Quick Troubleshooting; Firmware-Update Over The Air; Association - One Device Controls An Other Device; Configuration Parameters - Philio PHI PST02-1C Quick Start Manual

Z-wave 3 in 1 sensor door / window, illumination, temperature
Table of Contents

Advertisement

controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses o
device. To wakeup the device please perform the following action: Press any key once, the device will awake 10 seconds.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
1. Make sure a device is in factory reset state before including. In doubt exclude before include.
2. If inclusion still fails, check if both devices use the same frequency.
3. Remove all dead devices from associations. Otherwise you will see severe delays.
4. Never use sleeping battery devices without a central controller.
5. Dont poll FLIRS devices.
6. Make sure to have enough mains powered device to benefit from the meshing

Firmware-Update over the Air

This device is capable of receiving a new firmware 'over the air'. The update function needs to be supported by the central controller. Once the controller sta
update process, perform the following action to confirm the firmware update: The device support the Z-Wave firmware update via OTA. Before starting the p
please remove the front cover of the device. Otherwise the hardware check will be failed. Let the controller into the firmware update mode, and then press t
tamper key once to start the update. After finish the firmware download, the LED will start flash in every 0.5 second. At that time, please don"t remove the b
otherwise it will cause the firmware broken, and the device will no function. After the LED stop flash, it is recommended that the user power up the device. C
After remove the battery, please wait about 30
seconds, and then re-install the battery.

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a dif
device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they a
related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will rece
same wireless command wireless command, typically a 'Basic Set' Command.
Association Groups:
Group Number
1
2
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock fu
enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be t
value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same
applies: Values greater than 32768 may needed to be given as negative values too.
Parameter 2: Basic Set Level
Setting the BASIC command value to turn on the light
Size: 1 Byte, Default Value: 255
Setting
0
1 - 100
254
Parameter 4: Light Threshold
Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower then the threshold, the device will turn
light. 0 means turn off illumination detected function. And never turn on the light.
Notice: In none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value.
Size: 1 Byte, Default Value: 99
Setting
0
1 - 100
Parameter 5: Operation Mode
http://manual.zwave.eu/backend/make.php?lang=en&sku=PHI_PST02-1C
Maximum Nodes
Description
8
Receiving the report message, like triggered event, temperature, illumination etc.
Light control, the device will send the "Basic Set" command
8
Description
turn off the light
the light strength.
turn on the light.
Description
turn off illumination detected function.
1 means darkest. 99 means brightest. 100 means turn off illumination detected function. And always turn
light.