USER MANUAL – OPTIMA-T10 6K/10K (UL)
OPTIMA-T10 6K/10K (UL)
UPS ONLINE DOUBLE CONVERSION
VER.190731-GA2UL (ENG)
USER MANUAL
OPTIMA-T10-06K-230V (UL)
OPTIMA-T10-10K-230V (UL)
OPTIMA-T10-06K-ISOTX (UL)
OPTIMA-T10-10K-ISOTX (UL)
INDEX
VER. 1907.31
ENGLISH
TOWER
1

Advertisement

Table of Contents
loading

Summary of Contents for Integra Xmart OPTIMA-T10 6K/10K

  • Page 1 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) VER. 1907.31 ENGLISH USER MANUAL OPTIMA-T10 6K/10K (UL) UPS ONLINE DOUBLE CONVERSION TOWER OPTIMA-T10-06K-230V (UL) OPTIMA-T10-10K-230V (UL) OPTIMA-T10-06K-ISOTX (UL) OPTIMA-T10-10K-ISOTX (UL) www.xmart-ups.com VER.190731-GA2UL (ENG)
  • Page 2 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL)  Technical information on this manual is property of XMART This manual Information cannot be copied or distributed totally ▪ or partially without written approval of XMART. XMART can introduce modifications in their products or manuals without further notice. . ▪...
  • Page 3: Table Of Contents

    INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) TABLE OF CONTENTS 1. GENERAL SAFETY INSTRUCTIONS 2. SAFETY, QUALITY AND PERFORMANCE STANDARDS 3. PRODUCT DESCRIPTION 4. INSTALLATION 5. OPERATION MODES 6. OPERATION INTERFACE (KEYBOARD & LCD) 7. UPS CONFIGURATION 8. START-UP 9. ERROR & ALARMS CODES / TROUBLESHOOTING 10.
  • Page 4: General Safety Instructions

    INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) 1. GENERAL SAFETY INSTRUCTIONS WARNING: It is required to read and understand this manual. Follow all instructions given in this manual for starting up and operating this product. Only qualified technician must start-up, operate and maintain this product. Keep manuals as a guide for future consults. UPS manufacturer or distributor will never be responsible for any accident produced by lack of knowledge or negligent practices at the moment of install, starting up or maintain this product.
  • Page 5 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) 2. SAFETY, QUALITY AND PERFORMANCE STANDARDS SAFETY CONFORMANCE: UL 1778 CSA C22.2 SAFETY - LOW VOLTAGE DIRECTIVE (2006/95/EC) IEC/EN 62040-1 UPS Part 1-1: General & Safety UPS in accessible areas ELECTROMAGNETIC COMPATIBILITY FCC Part 15, Class A EMC DIRECTIVE (2004/108/EC) IEC/EN 62040-2 (Cat 3) UPS, Part 2, Electromagnetic Compatibility: Radiated &...
  • Page 6: Product Description

    INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) 3. PRODUCT DESCRIPTION This is an Uninterruptible Power Supply (UPS) ONLINE DOUBLE CONVERSION with IGBT technology at rectifier and inverter stages. It generates a pure SINEWAVE output free of noise and imperfections for powering and protecting your valuable system. This UPS is the right choice to protect hardware and data in critical workstations and server applications.
  • Page 7: Installation

    INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) 4. INSTALLATION This section of the manual includes installation procedure and instructions for this UPS series. Before doing installation, you must revise and understand sections related to safety and site conditions. SAFETY INSTRUCTIONS WARNING: Before revising this section, you must read and understand very well section 1 of this manual: “GENERAL SAFETY INSTRUCTIONS”.
  • Page 8 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) EN-IEC 62040-1: EXTERNAL BACKFEED PROTECTION In case back-feed protection is required, an automatic external protection circuitry must be installed to provide this kind of protection to comply with EN-IEC 62040-1. This external protection device is not included with this product. External back-feed device must be rated to drive maximum UPS current.
  • Page 9 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) SITE INSPECTION AND INSTALLATION CONDITIONS WARNING: This UPS must be connected with “TN” earthing system REGULATIONS AND LEGAL DIRECTIVES It is necessary to check that installation site, wiring and power protection in the installation supplied by end user, fulfill technical parameters required by UPS.
  • Page 10 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) EXTERNAL BATTERY CABINETS (XBAT) – CONNECTION PROCEDURE External batteries must be connected to UPS by using original XMART DC cable provided inside the box. IMPORTANT: All OPTIMA-T10 6K and 10K work with 240VDC battery voltage. This voltage is provided by battery packs by connecting 20 batteries 12VDC in series.
  • Page 11 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) CIRCUIT BREAKERS AND WIRING SELECTION Breakers and gauge of the wires used in input and output lines must be rated to drive current values in Amps as indicated in below tables. NOTE every country has its local electrical requirements and regulations. If local electrical regulations require higher rates than suggested values in this section, please follow local regulations.
  • Page 12 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) 4.1 INSTALLATION: INDIVIDUAL UPS – TERMINAL BLOCK AC LINES: CONNECTION IN UPS TERMINAL BLOCK Make sure the UPS is Off before starting the installation. ▪ Remember to check all wires to be connected are not powered (including external batteries). ▪...
  • Page 13 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) OPTIMA-T10 6K/10K ISOTX UPS with output ISOTX. ISOTX provides 2 separate 120Vac outputs that can be wired in 3 different configurations: 2 individual outputs120V: Each output can drive 50% of total UPS power. ▪...
  • Page 14 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) INSTALLATION: PARALLEL UPS – TERMINAL BLOCK OPTIMA-T10 & RT10 UPS allow connection in parallel up to 3 units. A system based on parallel UPS could offer a more reliable protection for the load in case it is dimensioned to work as redundant system. Parallel connection also allows system can grow in power by adding extra units.
  • Page 15 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) AC LINES: CONNECTION DIAGRAM OPTIMA-T10 & RT10 230 and OPTIMA-T10 & RT10 with optional ISOTX. OPTIMA-T10 RT10 6K/10K UPS with 220V output directly from inverter IMPORTANT: It is recommendable all output neutral lines are connected directly without breakers. It is important neutral lines are connected always since neutral is an important electrical reference for all UPS of the parallel system.
  • Page 16 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) OPTIMA-T10 6K/10K ISOTX : 1 x 120V To provide 1 output in 120Vac able to supply 100% of total UPS power, 2 individual 120Vac outputs must be connected by jumpers in terminal blocks (L1-L2 & N1-N2) as indicated in below figure. In case of 3 UPS, third UPS must be connected following same principle.
  • Page 17 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) OPTIMA-T10 6K/10K ISOTX: 2 x 120V With this configuration, each output will be able to provide 50% of total UPS power. In case of 3 UPS, third UPS must be connected following same principle. IMPORTANT: It is recommendable all output neutral lines are connected directly without breakers.
  • Page 18 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) OPTIMA-T10 6K/10K ISOTX: 1 x 220V To provide 1 output in 220Vac able to supply 100% of total UPS power, 2 individual 120Vac outputs must be connected in series by jumpers in terminal blocks (N1-L2) as indicated in below figure. In case of 3 UPS, third UPS must be connected following same principle.
  • Page 19 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) CONTROL CABLES: CONNECTION DIAGRAM Parallel system requires all UPS share some important control information by parallel control cables. There are 2 kind of control cables: SHARED CURRENT & PARALLEL CONTROL. They must be connected as indicated in below figure: www.xmart-ups.com VER.190731-GA2UL (ENG)
  • Page 20 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) 5. OPERATION MODES This is a True Online Double Conversion UPS and it is designed to offer clean, bump-less and highest quality power to your computer related equipment protecting also your valuable data. Power delivered by UPS is 100% sine wave as main line. According to AC main service, and how UPS has been configured, it may operate in following modes: ONLINE NORMAL Mode When UPS is off by selecting ON push button in front panel UPS enters ONLINE NORMAL mode if AC main service is inside acceptable...
  • Page 21 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) MAINTENANCE BYPASS BEFORE ACTIVATING ANY KIND OF EXTERNAL BYPASS SWITCH, UPS MUST BE SET IN INTERNAL STATIC BYPASS MODE. IF NOT INVERTER OUTPUT OF THE UPS WILL BE SHORTED WITH AC MAIN INPUT. THAT SITUATION COULD PRODUCE PERMANENT DAMAGE IN THE UPS.
  • Page 22: Operation Modes

    INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) OPERATION MODES LCD SCREENS (230VAC) LCD screens for 120V UPS models are similar but showing values related to 120V instead of 230V OPERATION MODE DESCRIPTION A- When bypass is not allowed UPS output is powered-off (0V).
  • Page 23 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) 6. OPERATOR INTERFACE: KEYBOARD & LCD LEDS DESCRIPTION: OPERATION MODE BYPASS LINE BATTERY FAULT ● ● ● ● UPS turning on ● ○ ○ ○ BYPASS active ○ ● ○ ○ NORMAL Online active ○...
  • Page 24 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) LCD DESCRIPTION LCD can be divided in 6 functional areas: OUTPUT INFORMATION: It displays: AC Input voltage, DC Battery voltage, Input frequency (in Hz) INPUT INFORMATION: It displays: AC output voltage, Output frequency (in Hz) ALARMS &...
  • Page 25 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) FLOWCHART – UPS STATES & MODES This section displays graphically operation mode and state of the UPS: (1) : Valid AC Input detected (2) : Battery symbol (3) : Converters (Rectifier & Inverter) (4) : UPS output powered (5) : BYAPSS internal static line active (6) : ECO mode active...
  • Page 26: Ups Configuration

    INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) 7. UPS CONFIGURATION Configuration menu allows setting of functions and parameters of the UPS. Menu is activated by pressing < TEST> < MUTE> at same time during 1 second with UPS in STAND-BY or BYPASS mode (powered but without activation of ON button).
  • Page 27 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) CONFIGURATION MENU: This model has configurable functions as listed in below table: OUTPUT VOLTAGE: - For 220V/230V models: Operator can select between: 208Vac / 220Vac / 230Vac / 240Vac. Factory set to: 230V - For 120V models: Operator can select between: 110Vac / 115Vac / 120Vac / 127Vac.
  • Page 28 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) ECO – INPUT VOLTAGE RANGE (Vac) Function 02: High Limit Function 03: Low Limit Set values with keys:  &  ECO – INPUT FREQUENCY RANGE (Hz) Function 02: High Limit Function 03: Low Limit Set values with keys: ...
  • Page 29 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) CHARGER VOLTAGE ADJUSTMENT: ** NO MODIFICATIONS RECOMMENDED – ONLY BY TECHNICIANS ** Charger voltage can be adjusted ADD: for increasing SUB: for decreasing Set values with keys:  &  INVERTER VOLTAGE ADJUSTMENT: ** NO MODIFICATIONS RECOMMENDED –...
  • Page 30 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) LCD CODES AND TEXTS: TEXT DESCRIPTION Battery (Batería) Frequency Converter Function Enable (Función de Convertidor de Frecuencia Activado) Frequency Converter Function Disable (Función de Convertidor de Frecuencia Desactivado) ON (Encendido) OFF (Apagado) Enable (Habilitado) Disable (Des-habilitado) Auto mode (Modo Automático) Subtract (Disminuir)
  • Page 31: Start-Up

    INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) 8. START-UP INSPECTION BEFORE START UP 1. Make sure all wires are tightly connected to terminal block. Any loose connection will produce overheating, failures and damage to UPS. 2. Make sure all instructions of installation sections have been performed correctly. 3.
  • Page 32 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) PARALLEL UPS - START-UP MANDATORY REQUIREMENTS FOR PARALLEL UPS If all these requirements are not complied parallel UPS will not be able to be started-up. 1.- Maximum quantity of UPS for working in parallel is 3 units 2.- All UPS must be same model and with compatible firmware.
  • Page 33 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) 14.- After confirming all output voltages in all units are similar, output breakers can be set ONE BY ONE in ON position. First UPS #1, then #2 and #3. At this moment AC outputs of all UPS are connected. 15.- Verify there is no error messages on LCDs.
  • Page 34 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) 9. ALARM & ERROR CODES / TROUBLESHOOTING IMPORTANT: All alarm and errors are informed don the LCD by dedicated codes and symbols. ▪ ALARMS: Are usually represented by blinking codes or symbols. Audible alarm beeps are also intermittent for alarms. Alarm ▪...
  • Page 35 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) ERROR CODES ERROR CONDITION ERROR CODE ERROR SYMBOL DC BUS start failure DC BUS High DC BUS Low DC BUS unbalanced INVERTER start failure INVERTER High voltage INVERTER Low voltage SHORT CIRCUIT detected at INVERTER output SHORT CIRCUIT detected at Battery SCR SHORT CIRCUIT detected at inverter output COMMUNICATION “CAN”...
  • Page 36 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) TROUBLESHOOTING PROBLEM PROBABLE CAUSE & SOLUCION Low Batteries Charge: Recharge Batteries during 4-6 h. Short runtime in Battery mode Old Batteries: Batteries must be replaced by new ones ALARMS PROBABLE CAUSE & SOLUCION High power consumption connected to UPS: Disconnect no critical equipment from UPS.
  • Page 37: Software

    INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) 10. SOFTWARE Our monitoring software allows user to manage UPS and monitoring of all of its features. Main software features are: Configuring UPS parameters, Automatic shutdown for protected PCs (OS and files) when long blackouts force UPS to power-off, Scheduled battery tests, shutdown and start-up and Easy interface for monitoring UPS and Main service.
  • Page 38: Support & Warranty

    INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) 13. SUPPORT & WARRANTY Support: If a failure or problem is detected please check troubleshooting section in user manual. If problem cannot be solved, please contact authorized service center or authorized dealer. Batteries: Rechargeable batteries can be charged and discharged hundreds of times. However, they will eventually wear out. This is not a defect or failure so that batteries wear out is not covered by this warranty.
  • Page 39: Rear Panel

    INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) 14. REAR PANEL 1 Terminal Block (AC input & output) 8 EPO: Emergency Power Off port 2 Auxiliary output IEC 220Vac 9 Parallel Control Ports: Shared Current 3 AC Input Breaker 10 Parallel Control Ports: Parallel Control 4 Maintenance Bypass Switch (MBS) 11 FAN: Power stage 5 DC connector for external batteries...
  • Page 40: Specifications

    INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) 15. SPECIFICATIONS (1/2) (6KVA-230 & 6KVA-ISOTX) (10KVA-230 & 10KVA-ISOTX) ONLINE - OPTIMA T10 (UL/CSA/CE) Capacity / Capacidad 6.000VA / 6.000W 10.000VA / 10.000W INPUT / ENTRADA Input Voltage / Voltaje de Entrada Rated Input / Entrada Nominal: 208/220/230/240 Vac (single phase: L-N-G) (110Vac-300Vac) @ 50% load Input Range / Rango de Entrada (176Vac-300Vac) @ 100% load...
  • Page 41 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) 15. SPECIFICATIONS (2/2) ONLINE - OPTIMA T10 (UL/CSA/CE) (6KVA-230 & 6KVA-ISOTX) (10KVA-230 & 10KVA-ISOTX) INDICATORS / INDICADORES UPS status, Load level, Battery, Input/Output voltage, Discharge timer, and Fault conditions LCD / Pantalla LCD Estado del UPS, Consumo, Baterías, Voltaje Entrada-Salida, Tiempo Descarga, Diagnostico ALARM / ALARMAS Beep Alarm / Alarma sonora:...
  • Page 42 INDEX USER MANUAL – OPTIMA-T10 6K/10K (UL) NOTAS www.xmart-ups.com VER.190731-GA2UL (ENG)
  • Page 44 USA Headquarters: EUROPE Headquarters: Latin America Headquarters: 10540 NW 26th St, Ave. Can Bordoll 60, Nave 4. Santiago de Chile, 8330669 Doral, FL 33172. USA Sabadell 08202. Spain Chile, CHILE...