Advertisement

Quick Links

www.xmart-ups.com
USER MANUAL - OPTIMA RT10 6K/10K-UL
OPTIMA RT10 6K/10K-UL
UPS ONLINE DOUBLE CONVERSION
RACK / TOWER INSTALLATION
VER.2106.21-One (ENG)
VER. 21.06.21
ENGLISH
USER MANUAL
OPTIMA-RT10-06K-230-UL
OPTIMA-RT10-10K-230-UL
ISOTX-06K-OPT-RACK-UL
ISOTX-10K-OPT-RACK-UL
INDEX
1

Advertisement

Table of Contents
loading

Summary of Contents for Integra Xmart OPTIMA-RT10-06K-230-UL

  • Page 1 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL VER. 21.06.21 ENGLISH USER MANUAL OPTIMA RT10 6K/10K-UL UPS ONLINE DOUBLE CONVERSION RACK / TOWER INSTALLATION OPTIMA-RT10-06K-230-UL OPTIMA-RT10-10K-230-UL ISOTX-06K-OPT-RACK-UL ISOTX-10K-OPT-RACK-UL www.xmart-ups.com VER.2106.21-One (ENG)
  • Page 2 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL Technical information on this manual is property of XMART  This manual Information cannot be copied or distributed totally ▪ or partially without written approval of XMART. XMART can introduce modifications in their products or manuals without further notice. . ▪...
  • Page 3: Table Of Contents

    INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL TABLE OF CONTENTS 1. GENERAL SAFETY INSTRUCTIONS 2. SAFETY, QUALITY AND PERFORMANCE STANDARDS 3. PRODUCT DESCRIPTION 4. INSTALLATION INSTALLATION INDIVIDUAL UPS INSTALLATION PARALLEL UPS 5. OPERATION MODES 6. OPERATION INTERFACE (KEYBOARD & LCD) 7.
  • Page 4: General Safety Instructions

    INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL 1. GENERAL SAFETY INSTRUCTIONS WARNING: It is required to read and understand this manual. Follow all instructions given in this manual for starting up and operating this product. Only qualified technician must start-up, operate and maintain this product. Keep manuals as a guide for future consults. UPS manufacturer or distributor will never be responsible for any accident produced by lack of knowledge or negligent practices at the moment of install, starting up or maintain this product.
  • Page 5: Safety, Quality And Performance Standards

    INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL 2. SAFETY, QUALITY AND PERFORMANCE STANDARDS SAFETY - LOW VOLTAGE DIRECTIVE (2006/95/EC) IEC/EN 62040-1 UPS Part 1-1: General & Safety UPS in accessible areas ELECTROMAGNETIC COMPATIBILITY - EMC DIRECTIVE (2004/108/EC) UPS, Part 2, Electromagnetic Compatibility: Radiated & Conducted IEC/EN 62040-2 (Cat 3) Low Freq.
  • Page 6: Product Description

    INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL 3. PRODUCT DESCRIPTION This is an Uninterruptible Power Supply (UPS) ONLINE DOUBLE CONVERSION with IGBT technology at rectifier and inverter stages with PWM. It generates a pure SINEWAVE output free of noise and imperfections for powering and protecting your valuable system. This UPS is the right choice to protect hardware and data in critical workstations and server applications.
  • Page 7: Installation

    INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL 4. INSTALLATION This section of the manual covers installation procedure and instructions for this UPS series. Before doing installation, you must revise and understand sections related to safety and site conditions. SAFETY INSTRUCTIONS WARNING: Before revising this section, you must read and understand very well section 1 of this manual: “GENERAL SAFETY INSTRUCTIONS”.
  • Page 8 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL EN-IEC 62040-1: EXTERNAL BACKFEED PROTECTION In case backfeed protection is required, an automatic external protection circuitry must be installed to provide this kind of protection to comply with EN-IEC 62040-1. This external protection device is not included with this product. External backfeed device must be rated to drive maximum UPS current.
  • Page 9 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL SITE INSPECTION AND INSTALLATION CONDITIONS REGULATIONS AND LEGAL DIRECTIVES It is necessary to check that installation site, wiring and power protection in the installation supplied by end user, fulfill technical parameters required by UPS. A particular installation might accomplish with UPS requirements but not with local directives and regulations.
  • Page 10 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL SITE INSTALLATION This UPS can be installed in both vertical format or inside a 19” rack cabinet. 19” RACK MOUNTING Rack UPS must be installed using L-Shape type guides for supporting UPS weight. Usually this kind of supports is provided with rack cabinets.
  • Page 11 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL VERTICAL MOUNTING UPS can be installed in vertical format by using plastic supports (Fig 1 & 2). These supports are included inside the box. 2 MODULES: UPS+XBAT: www.xmart-ups.com VER.2106.21-One (ENG)
  • Page 12 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL 3 MODULES: UPS+XBART+OPTIONAL ISOTX www.xmart-ups.com VER.2106.21-One (ENG)
  • Page 13 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL LCD ROTATION UPS display can be rotated 90º for easy reading in both vertical and horizontal installations. To rotate LCD follow next steps: Unlatch LCD according to step 1 Separate LCD from the UPS frame Rotate LCD as needed Re-install LCD in the UPS.
  • Page 14 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL CIRCUIT BREAKERS AND WIRING SELECTION Breakers and gauge of the wires used in input and output lines must be rated to drive current values in Amps as indicated in below tables. NOTE every country has its local electrical requirements and regulations. If local electrical regulations require higher rates than suggested values in this section, please follow local regulations.
  • Page 15: Installation Individual Ups

    INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL 4.1 INSTALLATION: INDIVIDUAL UPS – TERMINAL BLOCK Make sure the UPS is Off before starting the installation. ▪ Remember to check all wires to be connected are not powered (including external batteries). ▪ UPS + XBAT UPS with 220V output generated by UPS inverter.
  • Page 16 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL ISOTX (OPTIONAL MODULE) ISOTX module is an optional accessory not included with the UPS. It provides 2 galvanic isolated outputs 120V each. www.xmart-ups.com VER.2106.21-One (ENG)
  • Page 17 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL AC TERMINAL BLOCK CONNECTION BETWEEN UPS AND ISOTX UPS 240Vac output is connected to ISOTX input. ISOTX input generates 2 outputs of 120V. These 2 outputs can be wired as indicated in next section of this manual (ISOTX OUTPUT CONFIGURATION). www.xmart-ups.com VER.2106.21-One (ENG)
  • Page 18 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL ISOTX OUTPUTS CONFIGURATION ISOTX outputs can be connected in 3 different configurations according to below wiring diagrams: 2 individual outputs 120V (50% of UPS capacity each) ▪ 1 output 120V (100% of UPS capacity) ▪...
  • Page 19: Installation Parallel Ups

    INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL INSTALLATION: PARALLEL UPS – TERMINAL BLOCK OPTIMA T10 & RT10 UPS allow connection in parallel up to 3 units. A system based on parallel UPS could offer a more reliable protection for the load in case it is dimensioned to work as redundant system. Parallel connection also allows system can grow in power by adding extra units.
  • Page 20 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL AC LINES: CONNECTION DIAGRAM OPTIMA T10 & RT10 230 and OPTIMA T10 & RT10 with optional ISOTX. OPTIMA RT10 6K/10K UPS with 220V output directly from inverter IMPORTANT: It is recommendable all output neutral lines are connected directly without breakers. It is important neutral lines are connected always since neutral is an important electrical reference for all UPS of the parallel system.
  • Page 21 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL (UPS + ISOTX) : 1 OUTPUT x 120VAC To provide 1 output in 120Vac able to supply 100% of total UPS power, 2 individual 120Vac outputs must be connected by jumpers in terminal blocks (L1-L2 & N1-N2) as indicated in below figure. In case of 3 UPS, third UPS must be connected following same principle.
  • Page 22 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL (UPS + ISOTX) : 2 x 120VAC With this configuration, each output will be able to provide 50% of total UPS power. In case of 3 UPS, third UPS must be connected following same principle. IMPORTANT: It is recommendable all output neutral lines are connected directly without breakers.
  • Page 23 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL (UPS + ISOTX) : 1 x 220VAC To provide 1 output in 220Vac able to supply 100% of total UPS power, 2 individual 120Vac outputs must be connected in series by jumpers in terminal blocks (N1-L2) as indicated in below figure. In case of 3 UPS, third UPS must be connected following same principle.
  • Page 24 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL CONTROL CABLES: CONNECTION DIAGRAM Parallel system requires all UPS share some important control information by parallel control cables. There are 2 kind of control cables: SHARED CURRENT & PARALLEL CONTROL. They must be connected as indicated in below figure: www.xmart-ups.com VER.2106.21-One (ENG)
  • Page 25 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL 5. OPERATION MODES This is a True On Line Double Conversion UPS and it is designed to offer clean, bump-less and highest quality power to your computer related equipment protecting also your valuable data. Power delivered by UPS is 100% sine wave as main line. According to AC main service, and how UPS has been configured, it may operate in following modes: ONLINE NORMAL Mode When UPS is off by selecting ON push button in front panel UPS enters into ONLINE NORMAL mode if AC main service is inside acceptable...
  • Page 26 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL MAINTENANCE BYPASS From time to time, all UPS require some kind of maintenance that can only be performed if UPS is powered-off. In that case, an external maintenance bypass switch is actuated to keep system running by feeding it from the AC input service even UPS is powered-off. •...
  • Page 27: Operation Modes

    INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL OPERATION MODES LCD SCREENS (230VAC) LCD screens for 120V UPS models are similar but showing values related to 120V instead of 230V OPERATION MODE DESCRIPTION A- When bypass is not allowed UPS output is powered-off (0V).
  • Page 28 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL 6. OPERATOR INTERFACE: KEYBOARD & LCD UPS front panel is equipped with 4 buttons, 4 LEDs and a LCD display. LEDS DESCRIPTION: UPSMODE Bypass Line Battery Fault ● ● ● ● UPS turning on ●...
  • Page 29 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL LCD DESCRIPTION LCD can be divided in 6 functional areas: OUTPUT INFORMATION: It displays: AC Input voltage, DC Battery voltage, Input frequency (in Hz) INPUT INFORMATION: It displays: AC output voltage, Output frequency (in Hz) ALARMS &...
  • Page 30 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL FLOWCHART – UPS STATES & MODES This section displays graphically operation mode and state of the UPS: (1) : Valid AC Input detected (2) : Battery symbol (3) : Converters (Rectifier & Inverter) (4) : UPS output powered (5) : BYAPSS internal static line active (6) : ECO mode active...
  • Page 31: Ups Configuration

    INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL 7. UPS CONFIGURATION Configuration menu allows setting of functions and parameters of the UPS. Menu is activated by pressing < TEST> < MUTE> at same time during 1 second with UPS in STAND-BY or BYPASS mode (powered but without activation of ON button).
  • Page 32 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL CONFIGURATION MENU: This model has configurable functions as listed in below table: OUTPUT VOLTAGE: - For 220V/230V models: Operator can select between: 208Vac / 220Vac / 230Vac / 240Vac. Factory set to: 230V - For 120V models: Operator can select between: 110Vac / 115Vac / 120Vac / 127Vac.
  • Page 33 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL ECO – INPUT VOLTAGE RANGE (Vac) Function 02: High Limit Function 03: Low Limit Set values with keys:  &  ECO – INPUT FREQUENCY RANGE (Hz) Function 02: High Limit Function 03: Low Limit Set values with keys: ...
  • Page 34 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL CHARGER VOLTAGE ADJUSTMENT: ** NO MODIFICATIONS RECOMMENDED – ONLY BY TECHNICIANS ** Charger voltage can be adjusted ADD: for increasing SUB: for decreasing Set values with keys:  &  INVERTER VOLTAGE ADJUSTMENT: ** NO MODIFICATIONS RECOMMENDED –...
  • Page 35: Start-Up

    INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL 8. START-UP INSPECTION BEFORE START UP 1. Make sure all wires are tightly connected to terminal block. Any loose connection will produce overheating, failures and damage to UPS. 2. Make sure all instructions of installation sections have been performed correctly. 3.
  • Page 36: Parallel Ups

    INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL PARALLEL UPS - START-UP MANDATORY REQUIREMENTS FOR PARALLEL UPS If all these requirements are not complied parallel UPS will not be able to be started-up. 1.- Maximum quantity of UPS for working in parallel is 3 units 2.- All UPS must be same model and with compatible firmware.
  • Page 37 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL 14.- After confirming all output voltages in all units are similar, output breakers can be set ONE BY ONE in ON position. First UPS #1, then #2 and #3. At this moment AC outputs of all UPS are connected. 15.- Verify there is no error messages on LCDs.
  • Page 38 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL 9. ALARM & ERROR CODES / TROUBLESHOOTING IMPORTANT: All alarm and errors are informed on the LCD by dedicated codes and symbols. ▪ ALARMS: Are usually represented by blinking codes or symbols. Audible alarm beeps are also intermittent for alarms. Alarm ▪...
  • Page 39 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL ERROR CODES ERROR CONDITION ERROR CODE ERROR SYMBOL DC BUS start failure DC BUS High DC BUS Low DC BUS unbalanced INVERTER High voltage INVERTER Low voltage SHORT CIRCUIT detected at INVERTER output SHORT CIRCUIT detected at Battery SCR SHORT CIRCUIT detected at inverter output COMMUNICATION “CAN”...
  • Page 40 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL TROUBLESHOOTING PROBLEM PROBABLE CAUSE & SOLUCION Low Batteries Charge: Recharge Batteries during 4-6 h. Short runtime in Battery mode Old Batteries: Batteries must be replaced by new ones ALARMS PROBABLE CAUSE & SOLUCION High power consumption connected to UPS: Disconnect no critical equipment from UPS.
  • Page 41: Software

    INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL 10. SOFTWARE Our monitoring software allows user to manage UPS and monitoring of all of its features. Main software features are: Configuring UPS parameters, Automatic shutdown for protected PCs (OS and files) when long blackouts force UPS to power-off, Scheduled battery tests, shutdown and start-up and Easy interface for monitoring UPS and Main service.
  • Page 42: Support & Warranty

    INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL 13. SUPPORT & WARRANTY Support: If a failure or problem is detected please check troubleshooting section in user manual. If problem cannot be solved please contact authorized service center or authorized dealer. Batteries: Rechargeable batteries can be charged and discharged hundreds of times. However, they will eventually wear out. This is not a defect or failure so that batteries wear out is not covered by this warranty.
  • Page 43: Rear Panel

    INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL 14. REAR PANEL 1 Terminal Block (AC input & output) 8 EPO: Emergency Power Off port 2 Temperature input from ISOTX 9 Parallel Control Ports: Shared Current 3 AC Input Breaker 10 Parallel Control Ports: Parallel Control 4 Connector for Ext.
  • Page 44: Specifications

    INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL 15. SPECIFICATIONS (1/2) (RT10 6KVA-230) (RT10 10KVA-230) ONLINE - OPTIMA RT10 (UL) Capacity / Capacidad 6000VA / 6.000W 10000VA / 10.000W INPUT / ENTRADA Input Voltage / Voltaje de Entrada Rated Input / Entrada Nominal: 208/220/230/240 Vac (single phase: L-N-G) (110Vac-300Vac) @ 0-60% load (140Vac-300Vac) @ 61-80% load...
  • Page 45 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL 15. SPECIFICATIONS (2/2) (RT10 6KVA-230) (RT10 10KVA-230) ONLINE - OPTIMA RT10 (UL) BATTERIES / BATERIAS Type and Qty / Tipo y Cantidad Each XBAT / Cada XBAT 12V/7AH x 20 pcs (20pcs x 1: 240VDC) 12V/9AH x 20 pcs (20pcs x 1: 240VDC) Typical Recharge T.
  • Page 46 INDEX USER MANUAL - OPTIMA RT10 6K/10K-UL NOTAS www.xmart-ups.com VER.2106.21-One (ENG)
  • Page 48 USA Main Offices: EUROPE Main Offices: Latin America Main Offices: Doral, FL 33172. USA Sabadell 08202. Spain Santiago de Chile, Chile...

Table of Contents