Integra Xmart OPTIMA RT9W 6K User Manual

Integra Xmart OPTIMA RT9W 6K User Manual

Ups online double conversion rack / tower installation

Advertisement

Quick Links

www.xmart-ups.com
USER MANUAL - OPTIMA T09W 6K/10K
OPTIMA RT9W 6K/10K
UPS ONLINE DOUBLE CONVERSION
RACK / TOWER INSTALLATION
VER.1801.25-WP+ (ENG)
VER. 1801.25
ENGLISH
USER MANUAL
OPTIMA-RT9W-06K-230V
OPTIMA-RT9W-10K-230V
ISOTX-06K-OPT-RACK
ISOTX-10K-OPT-RACK
INDEX
1

Advertisement

Table of Contents
loading

Summary of Contents for Integra Xmart OPTIMA RT9W 6K

  • Page 1 INDEX USER MANUAL - OPTIMA T09W 6K/10K VER. 1801.25 ENGLISH USER MANUAL OPTIMA RT9W 6K/10K UPS ONLINE DOUBLE CONVERSION RACK / TOWER INSTALLATION OPTIMA-RT9W-06K-230V OPTIMA-RT9W-10K-230V ISOTX-06K-OPT-RACK ISOTX-10K-OPT-RACK www.xmart-ups.com VER.1801.25-WP+ (ENG)
  • Page 2 INDEX USER MANUAL - OPTIMA T09W 6K/10K  Technical information on this manual is property of XMART This manual Information cannot be copied or distributed totally ▪ or partially without written approval of XMART. XMART can introduce modifications in their products or manuals without further notice. . ▪...
  • Page 3: Table Of Contents

    INDEX USER MANUAL - OPTIMA T09W 6K/10K TABLE OF CONTENTS 1. GENERAL SAFETY INSTRUCTIONS 2. SAFETY, QUALITY AND PERFORMANCE STANDARDS 3. PRODUCT DESCRIPTION 4. INSTALLATION 5. OPERATION MODES 6. OPERATION INTERFACE (KEYBOARD & LCD) 7. UPS CONFIGURATION 8. START-UP 9. ERROR & ALARMS CODES / TROUBLESHOOTING 10.
  • Page 4: General Safety Instructions

    INDEX USER MANUAL - OPTIMA T09W 6K/10K 1. GENERAL SAFETY INSTRUCTIONS WARNING: It is required to read and understand this manual. Follow all instructions given in this manual for starting up and operating this product. Only qualified technician must start-up, operate and maintain this product. Keep manuals as a guide for future consults. UPS manufacturer or distributor will never be responsible for any accident produced by lack of knowledge or negligent practices at the moment of install, starting up or maintain this product.
  • Page 5: Safety, Quality And Performance Standards

    INDEX USER MANUAL - OPTIMA T09W 6K/10K 2. SAFETY, QUALITY AND PERFORMANCE STANDARDS SAFETY - LOW VOLTAGE DIRECTIVE (2006/95/EC) IEC/EN 62040-1 UPS Part 1-1: General & Safety UPS in accessible areas ELECTROMAGNETIC COMPATIBILITY - EMC DIRECTIVE (2004/108/EC) UPS, Part 2, Electromagnetic Compatibility: Radiated & Conducted IEC/EN 62040-2 (Cat 3) Low Freq.
  • Page 6: Product Description

    INDEX USER MANUAL - OPTIMA T09W 6K/10K 3. PRODUCT DESCRIPTION This is an Uninterruptible Power Supply (UPS) ONLINE DOUBLE CONVERSION with IGBT technology at rectifier and inverter stages with PWM. It generates a pure SINEWAVE output free of noise and imperfections for powering and protecting your valuable system. This UPS is the right choice to protect hardware and data in critical workstations and server applications.
  • Page 7: Installation

    INDEX USER MANUAL - OPTIMA T09W 6K/10K 4. INSTALLATION This section of the manual covers installation procedure and instructions for this UPS series. Before doing installation you must revise and understand sections related to safety and site conditions. SAFETY INSTRUCTIONS WARNING: Before revising this section you must read and understand very well section 1 of this manual: “GENERAL SAFETY INSTRUCTIONS”.
  • Page 8 INDEX USER MANUAL - OPTIMA T09W 6K/10K EN-IEC 62040-1: EXTERNAL BACKFEED PROTECTION In case backfeed protection is required, an automatic external protection circuitry must be installed to provide this kind of protection to comply with EN-IEC 62040-1. This external protection device is not included with this product. External backfeed device must be rated to drive maximum UPS current.
  • Page 9 INDEX USER MANUAL - OPTIMA T09W 6K/10K SITE INSPECTION AND INSTALLATION CONDITIONS REGULATIONS AND LEGAL DIRECTIVES It is necessary to check that installation site, wiring and power protection in the installation supplied by end user, fulfill technical parameters required by UPS. A particular installation might accomplish with UPS requirements but not with local directives and regulations.
  • Page 10 INDEX USER MANUAL - OPTIMA T09W 6K/10K SITE INSTALLATION This UPS can be installed in both vertical format or inside a 19” rack cabinet. 19” RACK MOUNTING Rack UPS must be installed using L-Shape type guides for supporting UPS weight. Usually this kind of supports is provided with rack cabinets.
  • Page 11 INDEX USER MANUAL - OPTIMA T09W 6K/10K VERTICAL MOUNTING UPS can be installed in vertical format by using plastic supports (Fig 1 & 2). These supports are included inside the box. 2 MODULES: UPS+XBAT: www.xmart-ups.com VER.1801.25-WP+ (ENG)
  • Page 12 INDEX USER MANUAL - OPTIMA T09W 6K/10K 3 MODULES: UPS+XBART+OPTIONAL ISOTX www.xmart-ups.com VER.1801.25-WP+ (ENG)
  • Page 13 INDEX USER MANUAL - OPTIMA T09W 6K/10K LCD ROTATION UPS display can be rotated 90º for easy reading in both vertical and horizontal installations. To rotate LCD follow next steps: Unlatch LCD according to step 1 Separate LCD from the UPS frame Rotate LCD as needed Re-install LCD in the UPS.
  • Page 14 INDEX USER MANUAL - OPTIMA T09W 6K/10K CIRCUIT BREAKERS AND WIRING SELECTION Breakers and gauge of the wires used in input and output lines must be rated to drive current values in Amps as indicated in below tables. NOTE every country has its local electrical requirements and regulations. If local electrical regulations require higher rates than suggested values in this section, please follow local regulations.
  • Page 15 INDEX USER MANUAL - OPTIMA T09W 6K/10K 4. INSTALLATION: TERMINAL BLOCK Make sure the UPS is Off before starting the installation. ▪ Remember to check all wires to be connected are not powered (including external batteries). ▪ UPS + XBAT UPS with 220V output generated by UPS inverter.
  • Page 16 INDEX USER MANUAL - OPTIMA T09W 6K/10K UPS + XBAT + ISOTX (OPTIONAL) ISOTX module is an optional accessory not included with the UPS. It provides 2 galvanic isolated outputs 120V each. UPS output is connected to ISOTX input. IMPORTANT: When ISOTX is connected, total power output is decreased in 7% because internal loses in the ISOTX.
  • Page 17 INDEX USER MANUAL - OPTIMA T09W 6K/10K ISOTX OUTPUTS CONFIGURATION ISOTX outputs can be connected in 3 different configurations according to the needs of the application. IMPORTANT: When 2 x 120V output configuration is selected, each output can only provide 50% of the total UPS output power.
  • Page 18 INDEX USER MANUAL - OPTIMA T09W 6K/10K 5. OPERATION MODES This is a True On Line Double Conversion UPS and it is designed to offer clean, bump-less and highest quality power to your computer related equipment protecting also your valuable data. Power delivered by UPS is 100% sine wave as main line. According to AC main service, and how UPS has been configured, it may operate in following modes: ONLINE NORMAL Mode When UPS is off by selecting ON push button in front panel UPS enters into ONLINE NORMAL mode if AC main service is inside acceptable...
  • Page 19 INDEX USER MANUAL - OPTIMA T09W 6K/10K MAINTENANCE BYPASS From time to time, all UPS require some kind of maintenance that can only be performed if UPS is powered-off. In that case, an external maintenance bypass switch is actuated to keep system running by feeding it from the AC input service even UPS is powered-off. •...
  • Page 20: Operation Modes

    INDEX USER MANUAL - OPTIMA T09W 6K/10K OPERATION MODES LCD SCREENS (230VAC) LCD screens for 120V UPS models are similar but showing values related to 120V instead of 230V OPERATION MODE DESCRIPTION A- When bypass is not allowed UPS output is powered-off (0V).
  • Page 21 INDEX USER MANUAL - OPTIMA T09W 6K/10K 6. OPERATOR INTERFACE: KEYBOARD & LCD UPS front panel is equipped with 4 buttons, 4 LEDs and a LCD display. LEDS DESCRIPTION: UPS MODE Bypass Line Battery Fault ● ● ● ● UPS turning on ●...
  • Page 22 INDEX USER MANUAL - OPTIMA T09W 6K/10K LCD DESCRIPTION LCD can be divided in 6 functional areas: OUTPUT INFORMATION: It displays: AC Input voltage, DC Battery voltage, Input frequency (in Hz) INPUT INFORMATION: It displays: AC output voltage, Output frequency (in Hz) ALARMS &...
  • Page 23 INDEX USER MANUAL - OPTIMA T09W 6K/10K FLOWCHART – UPS STATES & MODES This section displays graphically operation mode and state of the UPS: (1) : Valid AC Input detected (2) : Battery symbol (3) : Converters (Rectifier & Inverter) (4) : UPS output powered (5) : BYAPSS internal static line active (6) : ECO mode active...
  • Page 24: Ups Configuration

    INDEX USER MANUAL - OPTIMA T09W 6K/10K 7. UPS CONFIGURATION Configuration menu allows setting of functions and parameters of the UPS. Menu is activated by pressing < TEST> < MUTE> at same time during 1 second with UPS in STAND-BY or BYPASS mode (powered but without activation of ON button).
  • Page 25 INDEX USER MANUAL - OPTIMA T09W 6K/10K CONFIGURATION MENU: This model has configurable functions as listed in below table: OUTPUT VOLTAGE: - For 220V/230V models: Operator can select between: 208Vac / 220Vac / 230Vac / 240Vac. Factory set to: 230V - For 120V models: Operator can select between: 110Vac / 115Vac / 120Vac / 127Vac.
  • Page 26 INDEX USER MANUAL - OPTIMA T09W 6K/10K NOT USED IN THIS MODEL NOT USED IN THIS MODEL BYPASS – ENABLE / DISABLE: PAR 02: OPN: Allowed: according to PAR 03. FBD: Prohibited: BYPASS not allowed under any condition PAR 03: ENA: Enable: Bypass allowed in both manual and automatic. DIS: Disable: Automatic Bypass allowed but manual is prohibited Set values with keys: ...
  • Page 27 INDEX USER MANUAL - OPTIMA T09W 6K/10K NOT USED IN THIS MODEL INVERTER VOLTAGE ADJUSTMENT: ** NO MODIFICATIONS RECOMMENDED – ONLY BY TECHNICIANS ** Inverter voltage can be adjusted ADD: for increasing SUB: for decreasing Set values with keys:  &  CHARGER VOLTAGE ADJUSTMENT (IN FLOATING STATE): ** NO MODIFICATIONS RECOMMENDED –...
  • Page 28 INDEX USER MANUAL - OPTIMA T09W 6K/10K LCD CODES AND TEXTS: TEXT DESCRIPTION Battery (Batería) Frequency Converter Function Enable (Función de Convertidor de Frecuencia Activado) Frequency Converter Function Disable (Función de Convertidor de Frecuencia Desactivado) ON (Encendido) OFF (Apagado) Enable (Habilitado) Disable (Des-habilitado) Auto mode (Modo Automático) Subtract (Disminuir)
  • Page 29: Start-Up

    INDEX USER MANUAL - OPTIMA T09W 6K/10K 8. START-UP INSPECTION BEFORE START UP 1. Make sure all wires are tightly connected to terminal block. Any loose connection will produce overheating, failures and damage to UPS. 2. Make sure all instructions of installation sections have been performed correctly. 3.
  • Page 30 INDEX USER MANUAL - OPTIMA T09W 6K/10K 9. ALARM & ERROR CODES / TROUBLESHOOTING IMPORTANT: All alarm and errors are informed don the LCD by dedicated codes and symbols. ▪ ALARMS: Are usually represented by blinking codes or symbols. Audible alarm beeps are also intermittent for alarms. Alarm ▪...
  • Page 31 INDEX USER MANUAL - OPTIMA T09W 6K/10K ERROR CODES ERROR CONDITION ERROR CODE ERROR SYMBOL DC BUS start failure DC BUS High DC BUS Low DC BUS unbalanced INVERTER start failure INVERTER High voltage INVERTER Low voltage SHORT CIRCUIT detected at INVERTER output SHORT CIRCUIT detected at Battery SCR OVER TEMPERATURE OVERLOAD...
  • Page 32 INDEX USER MANUAL - OPTIMA T09W 6K/10K TROUBLESHOOTING PROBLEM PROBABLE CAUSE & SOLUCION Low Batteries Charge: Recharge Batteries during 4-6 h. Short runtime in Battery mode Old Batteries: Batteries must be replaced by new ones ALARMS PROBABLE CAUSE & SOLUCION High power consumption connected to UPS: Disconnect no critical equipment from UPS.
  • Page 33 INDEX USER MANUAL - OPTIMA T09W 6K/10K 10. SOFTWARE Our monitoring software allows user to manage UPS and monitoring of all of its features. Main software features are: Configuring UPS parameters Automatic shutdown for protected PCs (OS and files) when long blackouts force UPS to power-off Scheduled battery tests, shutdown and start-up.
  • Page 34: Support & Warranty

    INDEX USER MANUAL - OPTIMA T09W 6K/10K 13. SUPPORT & WARRANTY Support: If a failure or problem is detected please check troubleshooting section in user manual. If problem cannot be solved please contact authorized service center or authorized dealer. Batteries: Rechargeable batteries can be charged and discharged hundreds of times. However they will eventually wear out. This is not a defect or failure so that batteries wear out is not covered by this warranty.
  • Page 35: Rear Panel

    INDEX USER MANUAL - OPTIMA T09W 6K/10K 14. REAR PANEL 1 Terminal Block (AC input & output) 7 RS232 port 2 DC connector for external batteries 8 EPO port 3 AC Input Breaker 9 Ventilation grid 4 Connector for Ext. Bypass status signal (optional) 10 ISOTX: AC Input 5 Intelligent port 11 ISOTX: AC output...
  • Page 36 INDEX USER MANUAL - OPTIMA T09W 6K/10K 15. SPECIFICATIONS TABLE (1/2) (RT9W 6KVA-230) (RT9W 10KVA-230) ONLINE - OPTIMA RT9W Capacity / Capacidad 6.000VA / 5.400W 10.000VA / 9.000W INPUT / ENTRADA Input Voltage / Voltaje de Entrada Rated Input / Entrada Nominal: 208/220/230/240 Vac (single phase: L-N-G) (110Vac-300Vac) @ 50% load Input Range / Rango de Entrada (176Vac-300Vac) @ 100% load...
  • Page 37 INDEX USER MANUAL - OPTIMA T09W 6K/10K 15. SPECIFICATIONS TABLE (2/2) (RT9W 6KVA-230) (RT9W 10KVA-230) ONLINE - OPTIMA RT9W INDICATORS / INDICADORES UPS status, Load level, Battery, Input/Output voltage, Discharge timer, and Fault conditions LCD / Pantalla LCD Estado del UPS, Consumo, Baterías, Voltaje Entrada-Salida, Tiempo Descarga, Diagnostico ALARM / ALARMAS For Battery Mode, Low battery, Overload, UPS Failure / Beep Alarm / Alarma sonora:...
  • Page 38 INDEX USER MANUAL - OPTIMA T09W 6K/10K NOTES www.xmart-ups.com VER.1801.25-WP+ (ENG)
  • Page 40 USA Headquarters: EUROPE Headquarters: Latin America Headquarters: 10540 NW 26th St, Ave. Can Bordoll 60, Nave 4. Zona Ind. San Vicente II, C/ F, A11 Doral, FL 33172. USA Sabadell 08202. Spain Maracay. Venezuela sales@xmart-ups.com sales@xmart-ups.com sales@xmart-ups.com...

Table of Contents