SECTION 7 - TROUBLESHOOTING
TROUBLE
Powerpack (optional) motor does not start
Emergency stop button is engaged (PUSHED
IN) on powerpack
Direction selector or enable trigger or speed
control trigger not activated
Battery not installed or no charge
Motor has overheated
Platform does not lift up from bottom of travel - motor starts
Driveshaft interlock is engaged
(If using powerpack) Powerpack driveshaft not
engaged
Emergency brake not released from carriage
lock down latch position
1001070465
7-2
PROBABLE CAUSE
Disengage emergency stop button until it pops up (TURN CLOCKWISE).
Select 'UP' on direction selector, then activate both the enable trigger and speed
control continuously for operation.
Properly install charged battery in powerpack.
Wait until motor cools. The temperature cutout resets itself automatically.
Alternatively use manual descent procedure to lower platform (Section 4.1).
Push cordless drill on driveshaft down firmly to disengage driveshaft safety inter-
lock.
Check powerpack is correctly fitted to platform, latch is down and drive shaft is
connected to carriage drive shaft.
Ensure a load greater than 50kg (110 lbs.) is in the platform (1 person) and lifting
ropes are tight. If latch has not released, attempt to lower the loaded platform
slightly then try again to lift up.
REMEDY
LIFTPOD by JLG