Liquid velocity indication
Nº of digits:
Digit size:
General characteristics
Sensor materials:
MX4 converter material: Coated aluminium
Ingress protection:
Maximum cable length (remote version) : 150 m
Communication protocols (optional)
Detailed information on these protocols can be found in the R-IT-MX4COM instructions manual,
that can be downloaded from Tecfluid S.A. website.
14

MAINTENANCE

Sensor:
Electrode cleaning is recommended in installations where significant build ups or
sedimentation occur.
Cleaning can be done with detergent liquids and cleaning brushes of medium hardness.
Converter:
No special maintenance is required.
For external cleaning, a humid cloth can be used, and if necessary with a little neutral soap.
Solvents or other aggressive liquids which could damage the housing material should not be
used.
14.1

Fuse

In the event that the fuse blows, this should be replaced with a slow blow "T" fuse, size Ø5
x 20 mm and with the value indicated on the label inside the equipment.
5 (2 decimals)
11 mm
Body
EN 1.4404
(AISI 316L)
PVDF
Sensor: IP68, 10m H
MX4 converter: IP67
Modbus RTU
HART
Head
Electrodes
Hastelloy C22
PVDF
AISI 316L
Titanium
Zirconium
PVDF
Tantalum
O