Daily Safety Checklist - Assa Abloy Besam SW100 Owner's Manual

Low energy swing door operator
Hide thumbs Also See for Besam SW100:
Table of Contents

Advertisement

4
1003826-US-3.0
These minimum safety checks should be made each day and after any loss of electri-
cal power:
1. Activate the door. Door should open at a slow smooth pace (4 or more seconds),
and stop without impact.
2. Door must remain fully open for a minimum of 5 seconds before beginning to
close.
3. Door should close at a slow smooth pace (4 or more seconds), and stop without
impact.
4. Inspect the floor area. It should be clean with no loose parts that might cause user
to trip or fall. Keep traffic path clear.
5. Inspect the door's overall condition. The appropriate signage should be present
and the hardware should be in good condition.
6. Have door inspected by an AAADM certified inspector at least annually.
DO NOT USE DOOR if it fails any of these safety checks or if it malfunctions in
any way. Call a qualified automatic door service company to have door repaired
or serviced.
Issue 2007-08-24

Daily safety checklist

Apply to both sides of the door.
When using a wall switch,
apply to both sides of the door.
Apply the push decal to the push
side and the pull decal to the pull
side of the door.
Push plate
PRESS
TO OPEN
C L
Daily safety checklist
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents