Lutron Electronics HT-3007SD Operation Manual page 11

Sd card real time data recorder type k/j thermometer, dew point, wet bulb humidity/temp. meter
Table of Contents

Advertisement

6) Type K/J thermometer
a. Function select to " Type K/J thermometer "
b. Not install the Humidity " Probe Plug " ( 3-17,
Fig. 1 ) into the " Probe Input Socket " ( 3-7, Fig. 1 )
c. Plug the Thermocouple Temp. Probe ( Type K Temp.
probe pr Type J Temp. probe, optional ) into " Type
K/J Probe Input Socket " ( 3-8, Fig. 1 )
The Display will show the measuring value that
sensing from the Temp. probe.
d. If the Display show the indicator " K ", it is ready
for Type K thermometer.
If the Display show the indicator " J ", it is ready
for Type J thermometer.
Remark :
The meter is defaulted to " Type K thermometer ".
If intend to select the " Type J thermometer with
default , please refer chapter 7-5 ( page 19 ).
4-2 Data Hold
During the measurement, press the " Hold Button " ( 3-3,
Fig. 1 ) once will hold the measured value & the LCD will
display a " HOLD " symbol.
Press the " Hold Button " once again will release the data
hold function.
4-3 Data Record ( Max., Min. reading )
1) The data record function records the maximum and
minimum readings. Press the " REC Button " ( 3-4, Fig.
1 ) once to start the Data Record function and there
will be a " REC. " symbol on the display.
9

Advertisement

Table of Contents
loading

Table of Contents