VACUUM METER
Model : VC-9200
Your purchase of this VACUUM METER marks a step forward for
you into the field of precision measurement. Although this
METER is a complex and delicate instrument, its durable structure
developed. Please read the following instructions carefully and
always keep this manual within easy reach.
OPERATION MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Lutron Electronics VC-9200

  • Page 1 VACUUM METER Model : VC-9200 Your purchase of this VACUUM METER marks a step forward for you into the field of precision measurement. Although this METER is a complex and delicate instrument, its durable structure developed. Please read the following instructions carefully and always keep this manual within easy reach.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. FEATURES..............1 2. TYPICAL APPLICATION..........2 3. SPECIFICATIONS............2 3-1 General Specifications......... 2 3-2 Electrical Specifications........3 4. FRONT PANEL DESCRIPTION........4 4-1 Display............... 4 4-2 Power Button............4 4-3 Data Hold Button..........4 4-4 " Max./Min. " Button..........4 4-5 Unit Button............4 4-6 Battery Compartment/Cover........
  • Page 3: Features

    1. FEATURES * Absolute vacuum & absolute pressure measurement. * Wide measure range from 1 to 1500 mbar. * Overload protection up to 2000 mbar max. * Separate probe, easy operation. * Application : Automobile, Industrial, laboratory, heating, ventilation, medical hospital..* Heavy duty sensor used for air, oil gas, liquid.
  • Page 4: Typical Application

    2. TYPICAL APPLICATION * Measure pneumatic pressures. * Measure automobile engine pressures. * Pressure for super heat measurements. * Hydraulic servo controls. * Refrigeration. * Air conditioning. * Food processing. 3. SPECIFICATIONS 3-1 General Specifications Display 61 mm x 34 mm supper large LCD display.
  • Page 5: Electrical Specifications

    Power supply 006P DC 9V battery(heavy duty). Power current Approx. DC 7.1 mA. Vacuum 1/4" NPT or 1/4" PS sensor * Included one adapter connector that convert port Connector the 1/4" NPT to 1/4 " PS. Weight Instrument : 220 g/0.48 LB. Sensor probe : 183 g/0.4 LB.
  • Page 6: Front Panel Description

    4. FRONT PANEL DESCRIPTION Fig. 1 4-1 Display 4-8 RS-232 Output Terminal 4-2 Power Button 4-9 Port Connector ( 1/4" NPT ) 4-3 Data Hold Button 4-10 Vacuum Sensor Main body 4-4 " Max./Min. " Button 4-11 Plug of Vacuum Sensor 4-5 Unit Button 4-12 Adapter connector that 4-6 Battery Compartment/...
  • Page 7: Measuring Procedure

    5. MEASURING PROCEDURE 1) Plug the " Plug of Vacuum Sensor " ( 4-11, Fig. 1 ) into meter's " Sensor Input Socket " ( 4-7, Fig. 1 ). 2) Power on the meter by pressing the " Power Button " ( 4-2, Fig.
  • Page 8: Power Management

    8 ) For quick measurement, follow the procedures shown below : Main procedures : Connect the " Sensor Plug " to the meter's " Input Socket ". Power on the meter & select the display unit. Connect the pressure sensor connector with the equipment. Apply the equipment and get the pressure value.
  • Page 9: Auto Power Disable

    6. AUTO POWER OFF DISABLE The instrument has built-in " Auto Power Off " in order to prolong battery life. The meter will switch off automatically if no buttons are pressed for around 10 minutes. To inactivate this feature by pressing the " Max./Min. " button ( 4-4, fig.
  • Page 10 The 16 digit data stream will be displayed in the following format : D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 Each digit indicate the following status : End Word D1 & D8 Display reading, D1 = LSD, D8 = MSD For example : If the display reading is 1234, then D8 to D1 is :...
  • Page 11: Battery Replacement

    8. BATTERY REPLACEMENT 1) When the left corner of LCD display show " ", it is necessary to replace the battery. However, in-spec measurement may still be made for several hours after low battery indicator appears before the instrument become inaccurate. Slide the "...