Install The Fluid Supply - Graco BDS Instructions-Parts List Manual

Batch dispense system proportioning controller
Table of Contents

Advertisement

M
KEY
A
Pressure Tank
B
Air Regulator
C
Air Shutoff Valve
D
Fluid Shutoff Valve
E
Controller Assembly*
* The controller (E) is designed for use in a non-hazardous location as defined in the National Electrical Code (USA). To install the Batch
Dispense equipment in a Class 1, Division 1, Group C and D environment, the X-purge option (F) must be properly installed. Follow the
instructions on pages 60–66.
Figure 2 – Typical Installation

Install the Fluid Supply

Connect the fluid and air supply lines as shown in the
system and controller drawings starting on page 54.
The installation and operation instructions in this manu-
al generally presume a standard system, using pres-
sure tanks (A) to supply the paint components and sol-
vent. The optional fluid supplies listed below are
possible variations and their effect on the instructions.
Optional Fluid Supplies
Instead of pressure tanks (A), the BDS can be supplied
by pail or drum pumps or central paint recirculating
lines if they are available. An air piloted, fluid pressure
regulator is required on each supply line at the input to
the BDS.
12
309279
Installation
*E
G
J
L
K
Non hazardous Area
F
X-Purge Assembly*
G Dispense Valve
H
Fluid Regulator and
Gauge
F*
H
J
Valve Support
K
Stand and Frame
L
Scale
Other than references to the pressure tanks, operation
using other fluid supplies is the same as described in
this manual. For maintenance and safety, you must
install a fluid shutoff valve between each supply line
and the BDS.
The fluid supply must be free of pressure spikes, which
are commonly caused by a pump stroke changeover. If
necessary, install pressure regulators or a surge tank
on the fluid supply outlets. Note that this will also
reduce the fluid supply pressure.