Screen
Screen for Automatic Valves
Select a Valve Name or Valve Number to Edit Parameters
2
Valve #:
Valve Name:
Valve Name:
Valve #:
Valve Type:
Unit of Measure:
Specific Gravity:
Dispense Tolerance%:
VOC Content lbs/Gal:
Drop Time (milliseconds):
Circulate Interval (minutes):
Circulate Duration (minutes):
Minimum Flow Rate:
Maximum Flow Rate:
Add New
Screens for Manual Valves
Select a Valve Name or Valve Number to Edit Parameters
72
Valve #:
Valve Name:
Valve Name:
Valve #:
Valve Type:
Unit of Measure:
Specific Gravity:
Dispense Tolerance%:
VOC Content lbs/Gal:
Cancel
Select a Valve Name or Valve Number to Edit Parameters
70
Valve #:
Valve Name:
Valve Name:
Valve #:
Valve Type:
Unit of Measure:
Specific Gravity:
Dispense Tolerance%:
VOC Content lbs/Gal:
Add New
Delete Valve
Green
Green
1
Automatic
Pounds
0.959
5
5.23
7
5
2
10
25
Return to Main Menu
SW23
SW23
72
Manual
Pounds
0.959
5
4.76
Save Changes
Taupe
Taupe
1
Manual
Pounds
0.959
5
4.76
Return to Main Menu
Setup
How to Use
Edit Valve Parameters Screen
Press the Valve # or Valve Name down arrow to
select a different valve to edit.
To make changes to the parameters, press the
text box next to the parameter you want to
change. Type the new value in the box.
NOTE:
D Manual valve numbers are automatically as-
signed when using the Add Valve option. (Note
that if a valve is deleted, the valve number cannot
be reassigned.) The setpoints that you can edit
are:
D
Valve Name
D
Specific Gravity
D
Dispense Tolerance (whole num-
bers only)
D
VOC Content
D The VOC Content unit of measure is set during
System Setup (page 29).
D The Drop Time setpoint determines how long the
dispense valve actuates during the drop dispense
portion of a recipe step.
D The Circulate Interval setpoint determines the
length of time between valve recirculation cycles.
D The Circulate Duration setpoint determines the
length of time the valve recirculates.
D The Minimum Flow Rate setpoint determines
the minimum flow rate at which the dispense
valve will operate. It is also the rate at which the
step drop dispense occurs.
D The Maximum Flow Rate setpoint determines
the maximum flow rate at which the dispense
valve will operate.
When you are done editing the valve
parameters, press Save Changes.
Press Valve # or Valve Name down arrow to
select and edit another valve.
Press Return to Main Menu to exit the editing
screen.
–or–