Introduction; Attention - Toshiba nv Series Instruction Manual

Hide thumbs Also See for nv Series:
Table of Contents

Advertisement

Appendix E FL654 System View Screen Instruction Manual

Introduction

As the FL654 system view function support is now available on the FL911 module,
this operation manual is provided to describe how to use the FL654 operation
screens with the engineering tool. As for the tool screens, the path setting screen
for the FL654 module has been added to the FL654 module parameter screen. All
other screens remain unchanged.
Reference documents

Attention

The following transmission path is used for the FL654 system view function of the
FL911 module.
nv controller -> TC-net I/O interface -> FL911 -> FL654
When multiple transmission requests are sent to the FL654 module at the same
time, a transmission delay error may occur because the transmission path is
longer than that in the current setup, which is directly connected to the RS-232C
port. More specifically, the following cases may cause the error.
1) Transmission requests are sent at the same time from multiple computers in a
2) Transmission requests are made at the same time on multiple screens
If transmission delay occurs frequently, please reduce the number of transmission
requests.
To perform writing, including the mode change, and downloading on the FL654
module, it should be started up by turning on and off the DIP switches 3 and 4 of
the module. Refer to the reference document (
92
92
6F8C1375
Remark
・ The above function is supported from FL911 firmware version V01.10.
 Unified Controller nv series/Integrated Controller V series Engineering Tool 4
(Basic)
Instruction Manual
 model2000 FL-net(OPCN-2) Remote I/O Station Module(FL654)User's Manual
(6F8C1120) (*1)
client-server arrangement.
displayed on a single computer.
(6F8C1290)
*
1) for details.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fl911

Table of Contents