Baxi Ambiflo 75 Installation, Service & Maintenance Instruction page 34

Table of Contents

Advertisement

2. The installation must be protected by a double-pole circuitbreaker (not included). See the rating table
(Fig. 19).
Rating Table
Model
Voltage (v/Phase/Hz)
Nominal current (A)
Maximum current (A)
Starting current (A)
Protection rating (A)
Via Breaker class
Fig. 19
NOTE: The unit is designed to be connected to a power supply having a TT neutral
regime (neutral to ground) or T.N.S regime.
Power Supply Cable
3. The compressor start-up current for the Baxi Ambiflo™ Heat Pump is between 33A and 40A. This is a
transitory current that falls to between 12A and 16A in normal running mode dependant on model.
4. Make the electrical connections to the terminal board as per the electrical diagrams (Figs. 20 and 21).
Baxi Ambiflo™
Baxi Ambiflo™
75
90
230/1/50
230/1/50
12.4
15
14
8.2
40
33
16
16
C
C
Baxi Ambiflo™
5kW Electrical heater
105
230/1/50
230/1/50
16.7
22
21.3
-
34
-
32
32
C
B