NOZZLE INSTALLATION INSTRUCTIONS
After removing the current nozzle and ensuring that the nozzle O-ring (F) is properly seated in its groove,
twist the selected nozzle (E) clockwise (as viewed from the top) so that the flanges in the nozzle lock into
place on the top of the pump chamber by hand. Twist until the nozzle flanges can move no further and are
completely snug. Nozzles can be changed conveniently without removing the float or using any tools.
If it is difficult to twist the nozzle into place, dielectric grease (M) can be applied to the nozzle O-ring.
E
For Linden/Balsam Nozzles:
First ensure that the large Outlet nozzle is properly installed according to the above instructions. Insert the
Balsam or Linden components and thread into the insert at the top of the pump chamber, tightening every-
thing by hand until snug. Do not over-tighten.
Balsam
OUTLET (6) nozzle
F
Linden
installed