M O TO R ( 2 / 1 1 8 / JU ) 5 0 H Z
M O TO R ( 2 / 1 1 8 / JU ) 5 0 H Z
M O TO R ( 2 / 1 1 8 / JU ) 5 0 H Z
M O TO R ( 2 / 1 1 8 / JU ) 5 0 H Z
M O TO R ( 2 / 1 1 8 / JU ) 5 0 H Z
Part number:
Main winding:
Auxiliary-winding: 28,1
Voltage:
Current:
T he two-pole motor is connected directly to the
fan for internal air and via a gear to drive the drum.
On machines with condensers (T 720/ 780) it also
drives the fan for external air.
CAP ACI T
CAP
CAP
ACI T
ACI TO R
ACI T
O R
O R
O R
CAP
CAP
ACI T
O R
Part number:
T he capacitor is located on the motor and has a
value of 8µF.
CON DEN SED W A A A A A TER PU M P ( T7 2 0 / T7 8 0 )
CON DEN SED W
CON DEN SED W
CON DEN SED W
CON DEN SED W
H a n n i n g
H a n n i n g
H a n n i n g
2 5 W
H a n n i n g
H a n n i n g
2 5 W
Part number:
Resistance:
T he condensation water pump pumps the water
from the condenser housing at the rear of the machine
to the water tank.
RAD I O I N TERFEREN CE FI L
RAD I O I N TERFEREN CE FI LTER
RAD I O I N TERFEREN CE FI L
RAD I O I N TERFEREN CE FI L
RAD I O I N TERFEREN CE FI L
Part number:
Leakage current: 230 V/ 50 Hz 0.315 mA
The filter eliminates radio interference generated by
the machine.
I N D I CA
I N D I CA
TO R LAM P
TO R LAM P
I N D I CATO R LAM P
I N D I CA
I N D I CA
TO R LAM P
TO R LAM P
Part number:
Current:
T he lamp indicates that the main power switch is
set to on.
TH ERM I STO R ( T7 6 0 / T7 8 0 )
TH ERM I STO R ( T7 6 0 / T7 8 0 )
TH ERM I STO R ( T7 6 0 / T7 8 0 )
TH ERM I STO R ( T7 6 0 / T7 8 0 )
TH ERM I STO R ( T7 6 0 / T7 8 0 )
Part number:
Resistance:
The thermistor controls temperature regulation. If the
thermistor becomes short-circuited or disconnected
from the control unit, the program stops.
80 618 24
23,8
220/ 240 V
1,1 A, 270 W, 2850 rpm
80 542 68
TER PU M P ( T7 2 0 / T7 8 0 )
TER PU M P ( T7 2 0 / T7 8 0 )
TER PU M P ( T7 2 0 / T7 8 0 )
TER PU M P ( T7 2 0 / T7 8 0 )
2 5 W
2 5 W
2 5 W
80 638 09
111
TER
TER
TER
TER
80 585 58
80 070 73
1.68 mA, 230 V, 50 Hz
80 619 00
40-60 k
at 20°-30°C

COMPONENTS AND MEASUREMENT VALUES

CO N T
CO N T
ACT
ACT
O R
O R
CO N TACT
CO N T
CO N T
ACT
ACTO R
O R
O R
Part number:
Resistance:
T he contactor opens in case of overheating, when
the door is opened and at the end of the program.
TH ERM O ST
TH ERM O STA A A A A TS
TH ERM O ST
TH ERM O ST
TH ERM O ST
T7 0 0
T7 0 0
T7 0 0
T7 0 0
T7 0 0
Part number:
Low
Normal
Overheat
T he thermostats are located in the fan housing. It
controls the temperatures for the automatic
programs and the time program up to 60 minutes.
T he 239° F thermostat automatically disconnects
one of the heating loops if the temperature rises too
high. T his thermostat is located next to the heating
element at the rear of the dryer.
T7 2 0
T7 2 0
T7 2 0
T7 2 0
T7 2 0
Part number:
Low
Normal
T his thermostat is located in the fan housing. It
controls the temperature for the automatic programs
and the time program up to 60 min.
O V ERH EA
O V ERH EA
T PRO
T PRO
O V ERH EA
O V ERH EA
O V ERH EAT PRO
T PRO TECTI O N TH ERM O ST
T PRO
Part number:
T his thermostat stops the program if the
temperature rises too high. T he unit has to be
manually reset. It is located next to the heating
element at the rear of the dryer.
H U M I D I TY SEN SO R ( T7 6 0 / T7 8 0 )
H U M I D I TY SEN SO R ( T7 6 0 / T7 8 0 )
H U M I D I TY SEN SO R ( T7 6 0 / T7 8 0 )
H U M I D I TY SEN SO R ( T7 6 0 / T7 8 0 )
H U M I D I TY SEN SO R ( T7 6 0 / T7 8 0 )
Part number:
T he humidity sensor is used to control the drying
process. During operation the sensor output signal
is between 1 and 16 mV DC. Any other value causes
the program to stop.
O V ERFI LL PRO TECTI O N ( T7 2 0 / 7 8 0 )
O V ERFI LL PRO TECTI O N ( T7 2 0 / 7 8 0 )
O V ERFI LL PRO TECTI O N ( T7 2 0 / 7 8 0 )
O V ERFI LL PRO TECTI O N ( T7 2 0 / 7 8 0 )
O V ERFI LL PRO TECTI O N ( T7 2 0 / 7 8 0 )
Part number:
If both of the dryer containers are overfilled, the
program is stopped by a switch in the lower
container. T he LED window indicates overfilling.
80 091 48
2 k
TS
TS
TS
TS
80 619 46 (111° F/ 44°C)
80 014 45 (127° F/ 53°C)
80 088 07 (239° F/ 115° C)
80 144 44 (118° F/ 47° C)
80 560 29 (158° F/ 70° C)
TECTI O N TH ERM O STA A A A A T T T T T
TECTI O N TH ERM O ST
TECTI O N TH ERM O ST
TECTI O N TH ERM O ST
80 084 87 (302° F/150°C
manual)
80 618 55
80 526 43
15