INSTALLATION
ELECTRI CAL CO N N ECTI O N S
ELECTRI CAL CO N N ECTI O N S
ELECTRI CAL CO N N ECTI O N S
ELECTRI CAL CO N N ECTI O N S
ELECTRI CAL CO N N ECTI O N S
T he power supply cord must be grounded. If the
machine is to be used in a wet area, the supply must
be protected by a residual current device.
Connection to a permanently wired supply point
must be made only by a qualified electrician.
As supplied:
Single-phase, 208–240 V, 60 Hz,
2800 Watt total rating
2500 Watt heater rating
N OTE:
N OTE:
N OTE:
N OTE:
N OTE:
In Canada, the dryer is delivered ready-fitted with a
four-prong plug intended for connection to a single-
phase supply.
WARNING:
T he receptacle on the rear of the machine is
designed to accommodate ASKO washers ONLY
(rated 208–240 V .) To use this receptacle, you
must use the ready-fitted plug supplied with the
washing machine or an equivalent. T he supply
connection must be 2 0 8 – 2 4 0 V, 2 0 A.
ASKO washers rated 208–240 V have two internal
fuses of 15 A each.
8
Remove cover to
access terminal box.
(Requires a 20-Torx
screwdriver.)
Co n n e ct i n g a Th r e e
Co n n e ct i n g a Th r e e - w i r e P
Co n n e ct i n g a Th r e e
Co n n e ct i n g a Th r e e
Co n n e ct i n g a Th r e e
- w i r e P
- w i r e P
- w i r e P
- w i r e Po w e r Co r d
W ARN I N G!
W ARN I N G!
W ARN I N G!
W ARN I N G!
W ARN I N G!
Before starting this procedure, be sure the power
is turned off at the breaker/fuse box.
Power Suppl y Cord
You will need a three-wire power supply cord with
three No. 10 copper wires and a matching three-
wire receptacle of NEMA Type 10-30R, as illustrated
below:
1. Turn the power off at the breaker/ fuse box.
2. Remove terminal block cover (20 torx).
3. Assemble 3 /4 "
UL-listed strain
relief into the
hole below the
terminal block
opening.
4. Loosen
or
remove center
terminal block
screw .
5. Connect neutral
wire (white ) of
power supply
cord
to
the
center, silver-
colored terminal
screw. Tighten screw.
6. Connect the other wires to outer screws.
7. Tighten the strain relief screws.
8. Replace terminal box cover on back of dryer.
9. Plug dryer into wall receptacle.
10. Turn power on at breaker/ fuse box.
11. Turn on the main power switch on the dryer.
(T he power indicator light should come on.)