Component Description; Components And Measurement Values - Asko TD70.C Service Manual

Table of Contents

Advertisement

Service Manual TD70.C

Component description

Components and measurement values

The specified resistance values apply at room temperature (about 20°C/68°F). Values within
±10% are considered normal.
Article no.
Component
80 839 15
Motor 50 Hz,
220/240 V
80 839 16
Motor 60 Hz,
220/240 V
80 903 13
Capacitor
80 903 14
Capacitor
80 902 70
Capacitor heat pump
80 902 71
Capacitor heat pump
80 821 28
Condensate pump
80 846 48
Condensate pump
80 762 02
EMC-filter with inductor
80 833 44
Thermistor
80 773 85
Thermostat 150
80 792 00
Thermostat 135
80 902 24
Thermostat 110
80 761 04
Door switch
80 761 03
Microswitch float
Overflow guard
Electrical connection
80 824 92
Heating element 1950 W
80 915 90
Heating element 2500 W
80 824 91
Heating element 3000 W
80 824 60
Heating element 3000 W
80 824 61
Heating element 3000 W
80 916 18
Heating element 2500 W
80 821 30
Cooling fan compressor heat
pump
80 821 22
Base heat pump complete
80 821 23
Base heat pump complete
80 88 415
Reversing valve
80 841 00
Steam generator
80 902 22
Reed switch steam tank
80 889 37
Control unit compl. TD70.C
80 846 49
LED-light compl.
Measurement value
Winding resistance:
cable colour red-white 26.5 Ω
cable colour red-blue 53.5 Ω
cable colour white-blue 27.0 Ω
Current: 0.7 A; 140 W; 2850 rpm
Winding resistance:
cable colour red-white 26.5 Ω
cable colour red-blue 53.5 Ω
cable colour white-blue 27.0 Ω
Current: 0.7 A; 140 W; 3300 rpm
8 μF
6 μF
17 μF
4.8 kΩ (at 25°C)
150°C automatic
135°C automatic
110°C automatic
Condenser 1950W/10A-2500W/16A
Vented 1950W/10A-3000W/16A
Heat pump 1300W/10A
Heating Water Circuit 1950W/10A
Heater 1: 1950 W, 24.5 Ω
Heater 1: 1950 W, 24.5 Ω
Heater 2: 550 W, 91.4 Ω
Heater 1: 1950 W, 24.5 Ω
Heater 2: 1050 W, 45.5 Ω
Heater 1: 1950 W, 90.2 Ω
Heater 2: 1050 W, 167.6 Ω
Heater 1: 1950 W, 24,5 Ω
Heater 2: 1050 W, 45,5 Ω
Heater 1: 1950 W, 24,5 Ω
Heater 2: 550 W, 91,4 Ω
637 Ω
1.9 kΩ
68 Ω
Thermistor 61.4 kΩ
Steam pump 2.15 MΩ
Comment
The motor is a 2-pin motor and is directly
connected to the fan for internal air and the
gearing for driving the cylinder. On condenser
dryers, the motor also drives the fan for external
air.
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
The filter eliminates interference to and from the
machine.
The thermistor controls temperature regulation. If
the thermistor is short-circuited or detaches from
the control unit, the programme is stopped.
The thermostat/overheating cut-out stops the
programme if the temperature becomes too high.
The front door triggers a door switch which stops
the programme when the door is open. If the door
has been opened and closed during the programme
the machine must be restarted using the Start/Stop
button.
If both containers in the tumble dryer are full the
programme is stopped by a float switch installed
in the lower container. "Over flow" is indicated
on the display.
The machine is delivered as single phase and can
be switched between 10 A and 16 A. The control
buttons are used to make the switch via the software.
Does not apply to Heat Pump or Heating Water
Circuit.
Marine 440 V
3-Phase
3-Phase
50 Hz
60 Hz
Supplied with steam pump
The control unit contains microprocessors for
controlling programmes, the motor, the heating
elements etc.
LED-technology for the machine's internal light.
9

Advertisement

Table of Contents
loading

Table of Contents