Components And Measurement Values - Asko TD60 Service Manual

Tumble dryers
Hide thumbs Also See for TD60:
Table of Contents

Advertisement

Service Manual TD60.C

Components and measurement values

Item
Component
number
80 618 24
Motor 50 Hz,
220/240 V
80 618 95
Motor 60 Hz,
220/240 V
73 829 92
Capacitor 6 µF
80 546 40
Capacitor 4 µF
88 011 94
Condensing water pump 25 W
80 762 02
EMC fi lter
80 844 11
80 833 44
Thermistor
80 773 85
Thermostat/overheating cut-out
(150°C automatic)
80 796 00
Thermostat/overheating cut-out
(135°C automatic)
80 738 36
Door switch
80 761 03
Overfl ow cut-out
Electrical connection
8080604
Control unit
80 832 20
Heating element 2500 W
80 829 32
Heating Element 3000W
16
Measurement value
Primary winding: 23.8 
Auxiliary winding: 28.1 
Current: 1.1 A; 270 W; 2850
rpm
Winding resistance:
cable colour grey-blue 25.5 
cable colour grey-red 16.0 
Current: 0.9 A; 200 W; 3300
rpm
111 
40–60 k (at room tempera-
ture 20–30°C)
Heater 1: 1950 W, 24.5 
Heater 2: 550 W, 91.4 
Heater 1: 1950 W, 24.5 
Heater 2: 1050 W, 45.3 
Comment
The motor is a 2-pin motor and is directly connec-
ted to the fan for internal air and gearing for driving
the cylinder. On condenser dryers, the motor also
drives the fan for external air.
The capacitor is mounted on the motor.
The fi lter eliminates interference to and from the
machine.
The thermistor controls temperature regulation. If
the thermistor is short-circuited or detaches from
the control unit, the programme is stopped.
The thermostat/overheating cut-out stops the pro-
gramme if the temperature becomes too high.
The front door triggers a door switch, which stops
the programme when the door is open. If the door
has been opened and closed during the programme
the machine must be restarted using the start/stop
button.
If both tanks are full the programme is stopped by a
fl oat switch installed in the lower tank. Over fl ow is
indicated on the display.
The machine is delivered as single phase and can be
switched between 1950 W, 10 A and 2500 W, 16 A.
The buttons are used to switch between 1950 W /
10 A and 2500 W / 16 A via the software.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Td60.c

Table of Contents