Optional Function Setting Mode - Daikin LXE10E-A4 Service Manual

Marine type container refrigeration unit
Table of Contents

Advertisement

https://daikin-p.ru

10. OPTIONAL FUNCTION SETTING MODE

<Key operation to enter/exit>
Power OFF
Circuit Breaker ON
Unit OFF
I/O ON
All indication
lights on
(for 3 sec.)
for 3 sec.
F. PTI
Starting
S. PTI
preparation
M. CHECK
(for 18 sec.)
※ 1
Current
indication
(Operation state)
<Key operation in this mode>
Whenever the
key is pressed, the display changes.
S
Turn the power breaker OFF after the setting.
USDA SENSOR ON/OFF,
CARGO TEMPERATURE
SENSOR ON/OFF SETTING
S
S
DEHUMIDIFUCATION
CONTROL ON/OFF
SETTING
(conducting no dehumidifying) on the LED while the LCD indicates "dHU".
Whenever the
or
Press the
key to determine the setting.
Note : This setting can be changed by
(
I/O
I/O OFF
for 3 sec.
To set the USDA ON/OFF and CARGO TEMPERATURE SENSOR ON/OFF:
Select "OFF (not in use)", "3 (3 USDA probes are in use)", or "4 (3
USDA probes and 1 cargo temperature sensor are in use)" on the LED
while the LCD displays "USdA".
Whenever the
or "4" is changed.
Press the
Note: When two USDA probes are connected, the setting will be
determined automatically to "3" (3 USDA probes are in use).
To set the DEHUMIDIFICATION CONTROL:
Select "ON" (conducting dehumidifying with humidity sensor) or "OFF"
key is pressed, the indication of "ON" or "OFF" is changed.
key. (Refer to 3-12)
M
Circuit Breaker OFF
after setting change
OFF when no setting changed)
※ 10
Optional Function Setting
or
key is pressed, the indication of "OFF" or "3"
key to determine the setting.
3-26