3.6.1 Data logging

The data logging function is to store operation data which is generated during navigation.
There are seven kinds of logging data.
As to Tripdata, its logging interval can select from 15, 30, 60 (default) and 120 minutes.
※When F. PTI is executed, the logging interval become default (Refer to 3.9.2.3)
※Controller has Max. 2 years capacity at 60 min log interval.
Data name
1
ID data
2
Trip data
3
Alarm
4
PTI
5
USDA
(optional)
6
Event
7
USDA+CTS
(optional)
Logged data can be retrieved with the aid of personal computer software.
Refer to the Operation Manual for Personal Computer Software for detail.
¡Container No.
¡Departure port
¡Set point temperature
¡Set point ventilation flow rate
¡Set point humidity
¡Comment
¡Operation mode
¡Supply air temperature (SS)
¡Return air temperature (RS)
¡Inside humidity (optional)
¡Ambient temperature (AMBS)
¡Alarm output date/time
¡Alarm code
¡SHORT PTI
¡FULL PTI
¡Pulp sensor temperature (USDA #1 to #3)
¡Date/time
¡Logging interval is 1 hour.
¡Power ON/OFF
¡H code
¡D code
¡Pulp sensor temperature (USDA #1 to #3) and cargo sensor temperature
¡Date/time
3-38
Logging data
¡Loading date
¡Load
¡Transit place
¡Final destination
¡Navigation No.
¡Set point temperature
¡Set point humidity (optional)
¡Data recorder sensor temperature
(DSS/DRS) (optional)
¡Unit ON/OFF
¡Date/time
¡G-SET ON/OFF