3. BATTERY MODE
When commercial power is not available, the following functions are available by using the built-in wake up
battery.
• Indication of inside supply air temperature (SS) and return air temperature (RS)
• Setting for control temperature, control humidity and defrost interval
POWER OFF
Non operation
S
for 30 seconds
BATTERY MODE
Select an item using the
When no key operation is performed for 30 seconds in the BATTERY MODE, the battery mode turns off
automatically off.
Item
POWER OFF
S
RETURN AIR
TEMPERATURE DISPLAY
S
SUPPLY AIR
TEMPERATURE DISPLAY
S
CONTROL
TEMPERATURE DISPLAY
S
CONTROL
TEMPERATURE SETTING
S
CONTROL HUMIDITY
SETTING(optional)
S
S
DEFROST INTERVAL
SETTING
S
UNIT ON/OFF SETTING
Note 1). The inside sensor temperature is indicated on the section of ※※※.※.
CAUTION
To change to the BATTERY MODE, press the
the POWER OFF STATUS.
In the BATTERY MODE, return air temperature/supply air temperature
can be indicated, Control temperature, Control humidity (optional),
Defrosting interval and Unit ON/OFF key can be set.
key. The value of the selected item is indicated on the LCD screen.
S
LED display
–
(Light off)
(Light off)
(Light off)
(Light off)
(Light off)
(Light off)
(Light off)
If no indication on the LCD panel is displayed by
operating the key, it is supposed the wake-up battery is
dead.
Replace the battery.
3-11
LCD display
–
RS※※※.※C
Note 1)
SS※※※.※C
Note 1)
SP※※※.※C
Change the value using the
"SP C"
Press the
Setting temperature range; –30 to +30˚C.
Change the value using the
"SHU "
Press the
Setting humidity range: 60 to 95%RH
Select a defrost interval 99h, 24h,12h,9h,6h or
3h using the
"dEF H"
key to determine the setting.
"On demand defrosting" is conducted when
"99h" has been selected. (See page 2-20.)
Change the value using the
"UNIT ON" or
"UNIT OFF"
Press the
key while the unit is in
S
Setting method
–
–
–
–
key or
key to determine the setting.
key or
key to determine the setting.
key or
key. Press the
key or
key.
key to determine the setting.
key.
key.