Mode Operation - Daikin LXE10E-A4 Service Manual

Marine type container refrigeration unit
Table of Contents

Advertisement

https://daikin-p.ru

4. MODE OPERATION

MODE
M
Press the
key in current indication mode to go to MODE operation.
All indication
Lights on
(for 3 sec.)
Starting
Preparation
(for 18 sec.)
1
Current
indication
(Operation state)
MODE
M
MODE
OPERATION
In mode operation, the following settings/operations are available.
1. Generator setting
Total power consumption can be reduced to desired Max setting for the specific generators set or
power facilities.
The selections are "off (No limit)", "15" "14" "13" "12" "11" KVA.
2. Automatic pump down
Pump down can be executed automatically.
(Refer to "Automatic pump down" in 4.1.3)
3. LED display Light-OFF (OPTION)
All LED (includes LED lamp) can be switched off.
In order to execute this function, initial setting (Refer to initial setting in 3.8.2) shall be required to
change "on" position in advance.
4. Dehumidification mode setting
Dehumidification mode can be executed in this mode (M. Dehumidification mode control in 2.5.4).
When "Dehumidification" is set to "on", it is possible to change the following set from default.
qInside humidity : 95% (Default) ~30% RH
3-12