3.2.2 Operation mode and control

Operation mode
Operation
Set the set point
procedure
temperature at
+25 to –2.9˚C
(+77 to +26.8˚F).
Chilled mode operation
Function
is initiated.
Inside temperature is
controlled
proportionally in
modulation by the
supply air
temperature sensor.
Evaporator fans run at high speed
q Indicate the temperature data required to be converted into "˚F"
on the LED or the LCD.
Press the
converted into "˚F" for one minute.
※ If any other key is pressed during the "˚F" indication, the display
switches to "˚C".
「℃」display
qPress the MANUAL DEFROST
wSelect "ON" indicated on the LED display using the
key, and press the
defrost operation starts.
※Once defrosting operation starts, the operation mode is not
changeable until the defrosting operation completes. If this key is
pressed during the defrosting operation, it is ineffective.
※Defrosting will not start when the evaporator outlet temperature is
20˚C or higher or the inlet temperature is 5˚C or higher.
Chilled mode
Partial frozen mode
Set the set point
temperature at
– 3.0 to –10.0˚C
(+26.6 to +14˚F).
Partial frozen mode
operation is initiated.
Inside temperature is
controlled through
modulation by the
return air
temperature sensor.
DISPLAY
C ˚
key, then the temperature data displayed in "˚C" is
F ˚
MANUAL
DEFROST
key to determine the setting, then the
Setting temperature
Set the set point temperature at
–10.1 to –30.0˚C (+13.8 to –22˚F).
Frozen mode operation is initiated.
Inside temperature is controlled by
cycling ON/OFF of compressor by the
return air temperature sensor.
Evaporator fans run at low speed
3-5
「°F」display
key.
key or the
Frozen mode