Configuration And Operation; Initial Start-Up; Signal Elements - Kaco blueplanet 3.0 TL3 M2 WM OD IIG0 Manual

Hide thumbs Also See for blueplanet 3.0 TL3 M2 WM OD IIG0:
Table of Contents

Advertisement

9 | Configuration and operation

9
Configuration and operation
9.1

Initial start-up

When started for the first time, the device displays the configuration assistant. It takes you through the settings
necessary for the initial start-up.
NOTE
After configuration is completed, the configuration assistant does not appear again when the device is restar-
ted. You can then change the country setting only in the password-protected parameter menu. The other set-
tings can still be changed in the Settings menu.
1. In order to select a setting, press the Up and Down buttons.
2. To select the next menu option, press the Enter button.
3. To return to the most recently selected menu option, press the ESC button.
4. Set the required settings.
5. In the last menu option, press the Enter button.
Configuration assistant
1. Select the menu language.
2. Select the country of operation with grid type.
3. Set the date and time.
4. To store the set operator country and grid type permanently, confirm with "Yes".
ð You have completed the initial configuration. The device begins operation.
9.2

Signal elements

The 3 LEDs on the device control panel show the different operating states. The LEDs can display the following
states:
LED illuminated
Operating status
Start
Feed-in start
Feed-in operation
Feed-in mode with re-
duced power
3
*) The waiting period ensures that the generator voltage continuously remains above the power delivery limit
of 200 V. For country-specific waiting periods see our website.
Page 32
LED flashing
LED
Icon
Display
Power fed into the grid or
measured values
Power fed into the grid or
measured values
Power fed into the grid
or measured values
KACO blueplanet 3.0 TL3 KACO blueplanet 4.0 TL3 KACO blueplanet 5.0 TL3 KACO blueplanet 6.5 TL3 KACO
blueplanet 7.5 TL3 KACO blueplanet 8.6 TL3 KACO blueplanet 9.0 TL3 KACO blueplanet 10.0 TL3
Manual
LED not illuminated
Description
The green "Operation" LED is on
when the AC voltage is present, inde-
pendent of the DC voltage.
The green "Operating" LED is lit.
The green "Feed-in" LED is lit after
the country-specific waiting period
Ready for grid operation.
The interface switch engages audibly.
The green "Operating" LED is lit.
The green "Feed-in" LED is lit.
The "Feed-in" icon appears on the
LD display.
The device feeds into the grid.
The green "Operating" LED is lit.