Remove the safety screen and glass door, refer to the "SAFETY SCREEN INSTALLATION /
B.
REMOVAL" & "DOOR INSTALLATION / REMOVAL" sections for details.
Disconnect the Lamp power cable plug attached to the Fireplace Control Module (FCM) from the
C.
LED control power adapter.
Depress securing tab and disconnect white and black connectors from LED lights.
D.
NOTE: Extreme caution required when handling fragile connections.
Disconnect both insulated terminal connectors.
E.
Remove resistor wires from wire clips.
F.
Remove existing LED control with wire harnesses and discard. Apply velcro strips (supplied) to new
G.
LED control housing, peel adhesive backing and secure near right side of LED lights. HINT: Use
cable ties to contain wires in an organized manner.
Connect white and black connectors to LED lights.
H.
NOTE: Extreme caution required when handling fragile connections.
Remove resistor wires from wire clips.
I.
Connect both insulated terminal connectors (not polarity specifi c).
J.
Clip resistor wires into wire clips.
K.
Disconnect wires then remove screws and existing FCM.
L.
NOTE: Label wires when disconnecting from existing FCM.
Replace with new FCM and reconnect wires.
M.
NOTE: Grounding wire must be resecured between screw and FCM.
Connect LED control power adapter to Lamp power cable on FCM.
N.
Apply velcro strips (supplied) to Bluetooth control housing, peel adhesive backing and secure in a
O.
convenient location near FCM.
NOTE: Do not cover Bluetooth control.
Connect black/white cable from Bluetooth control to Diagnostic Interface (connection XOA) on FCM.
P.
Connect green 2-pin jumper to Bluetooth control.
Q.
Connect black/red cable from Bluetooth control to black cable from LED control.
R.
Reconnect power supply to the appliance.
S.
Test LED lights and Bluetooth control. See "eFIRE MOBILE APPLICATION" leafl et.
T.
Turn on gas and reinstall door, lower trim piece and safety barrier.
U.
9.2

eFIRE CONTROLLER APPLICATION

Refer to the eFIRE controller application leafl et supplied for detailed operating and connection instructions.