Annual Maintenance; Control Access - Napoleon LV50N2 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

60
11.1

ANNUAL MAINTENANCE

EN
EN
THE FIREBOX BECOMES VERY HOT DURING OPERATION. LET THE APPLIANCE COOL
COMPLETELY OR WEAR HEAT RESISTANT GLOVES BEFORE CONDUCTING SERVICE.
This appliance will require maintenance which should be planned on an annual basis.
Service should include cleaning, battery replacement, venting inspection and inspection of the burner,
media and fi rebox. Refer to the door removal section and remove the door as instructed.
Carefully remove media if necessary (logs, glass, brick panels etc).
Using a vacuum with a soft brush attachment, gently remove any dirt, debris or carbon build up from the
logs, fi rebox and burner. For glass media, follow the installation instructions for pre-cleaning.
Also gently remove any build-up on the pilot assembly including, if equipped; thermopile, thermocouple,
fl ame sensor and igniter. NOTE: Clean fl ame sensor using a fi ne emery cloth or a synthetic scrub pad
(such as Scotch-Brite™) to remove any oxides. Clean the pilot assembly using a vacuum with a soft
brush attachment. It is important that the pilot assembly is not painted.
Inspect all accessible gaskets and replace as required.
Access the blower, if equipped and clean using a soft brush and vacuum.
Re-assemble the various components in reverse order.
Inspect the relief system. The appliance relieves through the main glass door or through the fl aps on the
fi rebox top. Ensure they open freely, and close sealed.
Check the gas control valve pilot and Hi / Lo knobs move freely (if equipped) – replace if any stiffness in
movement is experienced.
Check for gas leaks on all gas connections up and downstream from the gas valve including the pilot
tube connections.
11.2

CONTROL ACCESS

Access to the control can be done through the fi rebox by removing the safety screen, glass door and front trim.
VALVE
W415-1624 / D / 11.22.16
WARNING
!
NEVER VACUUM HOT EMBERS.
DO NOT PAINT THE PILOT ASSEMBLY.
CONTROL
ELECTRICAL
MODULE
LV50 ILLUSTRATED
BOX
37.1E

Advertisement