General Information - Napoleon LV50N2 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

2.3

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
Altitude (FT)
Max. Input (BTU/HR)
Min. Input (BTU/HR)
P4
Min. Inlet Gas Supply
Pressure
Max. Inlet Gas Supply
Pressure
Manifold Pressure (Under
Flow Conditions)
When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specifi c recommendations
from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for
each additional 1,000ft (305m). Expansion / contraction noises during heating up and cooling down cycles are
normal and are to be expected. Change in fl ame appearance from "HI" to "LO" is more evident in natural gas
than in propane.
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is certifi ed for mo-
bile home installation.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certifi ed kit is used.
There are two switches that control the function of the appliance. One on the receiver that must be placed in
the middle position. The other is on the control module that must be in the "I" position, which denotes on. If
these switches aren't in these locations the appliance will not work.
NOTE: The protective wrap on plated parts is best removed when the assembly is at room temperature
but this can be improved if the assembly is warmed, using a hair dryer or similar heat source.
This appliance is equipped with a remote control system, which requires batteries to be installed. The trans-
mitter takes 3 "AAA" batteries and in the case of a power failure the receiver takes 4 "AA" batteries.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance
and must be installed.
LV50N
NG
P
0-4,500
0-4500
40,000
40,000
26,000
32,000
49%
49%
4.5" wc (11mb) 11" wc (27mb)
13" wc (17mb) 13" wc (32mb)
3.5" wc (9mb)
10" wc (25mb)
LV50N2
NG
P
0-4,500
0-4500
40,000
40,000
26,000
32,000
54%
54%
4.5" wc (11mb)
11" wc (27mb)
13" wc (17mb)
13" wc (32mb)
3.5" wc (9mb)
10" wc (25mb)
W415-1624 / D / 11.22.16