Special Vent Installation; Periscope Termination - Napoleon LV50N2 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

12
SINGLE-SIDED OR
SEE-THROUGH
EN
EN
3.3

SPECIAL VENT INSTALLATION

3.3.1 PERISCOPE TERMINATION

Use the periscope kit to locate the air termination above grade. The periscope must
be installed so that when fi nal grading is completed, the bottom air slot is located a
minimum 12" (30.5cm) above grade. The maximum allowable vent length is 10' (3m)
for a fi replace and 8' (2m) for a stove.
W415-1624 / D / 11.22.16
16" (40.6cm)
MINIMUM
40 FT (12M)
MAXIMUM
3 FT (1M)
MINIMUM
(83.8cm)
32 1/4" (81.9cm)
MINIMUM
33"
(83.8cm)
33"
12"
(30.5cm)
MIN TO
GRADE
9.1B