Using Flexible Vent Components; Horizontal Air Terminal Installation - Napoleon LV50N2 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

22
4.2

USING FLEXIBLE VENT COMPONENTS

EN
EN
DO NOT ALLOW THE INNER FLEX PIPE TO BUNCH UP ON HORIZONTAL OR VERTICAL RUNS AND ELBOWS.
SPACERS ARE ATTACHED TO THE INNER FLEX PIPE AT PREDETERMINED INTERVALS TO MAINTAIN AN EVEN
AIR GAP TO THE OUTER FLEX PIPE. THIS GAP IS REQUIRED FOR SAFE OPERATION. A SPACER IS REQUIRED
AT THE START, MIDDLE AND END OF EACH ELBOW TO ENSURE THIS GAP IS MAINTAINED. THESE SPACERS
ELBOW

4.2.1 HORIZONTAL AIR TERMINAL INSTALLATION

A.
Stretch the inner fl ex pipe to the required length needed
for the fi nished wall surface. Apply a heavy bead
of a heavy bead of the Mill Pac sealant (W573-
0007) (not supplied) to the inner sleeve of the
air terminal. Slip the vent pipe a minimum of 2"
(50.8mm) over the inner sleeve of the air terminal
and secure with 3 #8 screws.
B.
Using the outer fl ex pipe, slide over the outer
combustion air sleeve of the air terminal and secure
with 3 #8 screws. Seal using Red RTV Silicone
(W573-0002)
C.
Insert the vent pipes through the fi restop
maintaining the required clearance to
combustibles. Holding the air terminal (lettering
in an upright, readable position), secure to the
exterior wall and make weather tight by sealing
with caulking (not supplied).
D.
If more vent pipe needs to be used to reach the
fi replace, couple them together as illustrated. The
vent system must be supported approximately
every 3 feet (0.9mm) for both vertical and
horizontal runs. Use noncombustible strapping to
maintain the minimum 1" (25.4mm) clearance to combustibles.
The air terminal mounting plate may be recessed into the exterior wall or siding no greater than the depth
of its return fl ange.
W415-1624 / D / 11.22.16
KEEP IT PULLED TIGHT.
MUST NOT BE REMOVED.
For safe and proper operation of the appliance, follow the venting
instructions exactly.
All inner fl ex pipe and outer fl ex pipe joints may be sealed using high
temperature red RTV silicone W573-0002 (not supplied) or the high
temperature sealant W573-0007 Mill Pac (not supplied). However, the high
temperature sealant W573-0007 Mill Pac (not supplied) must be used on
SPACERS
the joint connecting the inner fl ex pipe and the exhaust fl ue collar.
Use only approved fl exible vent pipe kits marked:
"Wolf Steel Approved Venting" as identifi ed by
the stamp only on the outer fl ex pipe.
WARNING
!
#10x2"
SCREWS
HI-TEMP
SEALANT
OUTER
FLEX PIPE
22.1A
CAULKING
OUTER FLEX PIPE
2" (50.8mm) OVERLAP
HIGH TEMPERATURE
SEALANT
#8 X 1/2" SELF DRILLING
SCREWS
INNER COUPLER
OUTER COUPLER
OUTER
FLEX PIPE
INNER
FLEX PIPE
23.3C