Schematic - Napoleon LV50N2 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

48
7.4

SCHEMATIC

EN
EN
NOTE: This appliance is equipped with a three-prong (grounding) plug for protection against shock
hazard and should be connected into a properly grounded circuit. Do not cut or remove the grounding
prong from the plug.
W415-1624 / D / 11.22.16
!
DO NOT WIRE 110 VOLTS TO THE VALVE OR WALL SWITCH.
*
LAMP
COMFORT
FAN
WARNING
*
OPTIONAL BLOWER
COMFORT
FAN
1.
Unplug the blower/lamp terminal block.
2.
Loosen blower terminal screws and disconnect
the blower wires as shown below.
3.
Disconnect the blower ground wire.
4.
Connect new house sires into the blower terminal
block and tighten the blower terminal screws.
5.
Plug the blower/lamp terminal block back into the
board.
6.
Ensure to ground new house wire to the ground
screw.
7.
Connect the other end of the house wires to the
junction box of the optional blower.
BLOWER/LAMP
TERMINAL BLOCK
LAMP
REMOVE WIRES TWO BLOWER
WIRES AS SHOWN
BLOWER
LAMP
BLOWER/LAMP TERMINAL
BLOCK (TOP VIEW)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lv50nLv50pLv50p2

Table of Contents