Notes:

2.5 Special operations

2.5.1

Scaling factor

2.5.2

Part centering

Note:
(10/29) - DRO operation - Installation/Operation - 10i / 20i - V0703
If installation parameter PAR11=1, the presetting sequence is: [ENTER] [axis]
[value] [ENTER].
Switching over to [ABS] mode, displays the distance to part zero (datum).
It is possible to apply a scaling factor within ±9.999 for mold making
applications:
The DRO will then show the axis position resulting from multiplying its real
position by the 'value' of the scaling factor.
This feature is available when none of the axes have installation
parameter PAR04(2)=1 (radius/diameter commutable).
Part centering can be done as follows:
- Set the dro in absolute mode.
- Touch one side of the part with the tool.
- Set the reading to zero pressing for an axis [CLEAR] [X] for one axis or
[CLEAR] [Y/Z] for the other one (20i).
- Take the tool to the other side of the part and touch this with it.
- Press the sequence [1/2] [X] for one axis or [1/2] [Y/Z] for the other (20i).
The DRO will display half of the distance covered by the tool.
- Retract the axes until the displays read 0.0000, the tool can be placed
exactly at the center of the part.