Easy Setup; Accessing The "Easy Setup" Mode; Operating Mode - Fagor Innova 10i Installation & Operation Manual

Table of Contents

Advertisement

3.5 Easy setup

3.5.1

Accessing the "Easy Setup" mode

CODE: 555
3.5.2

Operating mode.

(14/29) - DRO installation - Installation/Operation - 10i / 20i - V0703
Feedback connection. Connectors X1 and X2
Pin
1
2
3
4
5
6
7
8
9
10
Not connected
11
12, 13, 14
Not connected
15
The "Easy Setup" may be used to set up the feedback of the DRO and to
verify that the installation is correct and no feedback pulses are missed.
It sets up the encoder resolution and the kind of reference marks being used
as well as the positive counting (reading) direction.
Press [CLEAR] [OFF]
And, instead of entering the parameters accessing code, key in: 555
The axes displays will show "Setup" meaning that the feedback is not set up
yet.
• Move the axis to the origin or zero point and press the axis key.
The display shows "START".
• Move the axis in the positive direction all the way to the end of the travel so
the DRO can read as many reference marks as possible.
• Press [ENTER] to finish. The moving direction used will be assumed as the
positive direction.
Signal
A
/A
B
Input for feedback signals
/B
I0
/I0
Alarm
/Alarm*
+5V
Power supply to feedback devices
0V
Power supply to feedback devices
Chassis
Function
Shield

Advertisement

Table of Contents
loading

This manual is also suitable for:

Innova 20iInnova 10i-bInnova 20i-b

Table of Contents