Dro Description; Front Panel - Fagor Innova 10i Installation & Operation Manual

Table of Contents

Advertisement

1.1 Front panel

Description of LED's and keys:
ABS
INCH
Each axis display has eight 14.1mm high LEDs and another one for the minus
sign (-).
It stays on when operating in absolute mode and off when in incremental
mode. To access it or quit it, press this key.
Φ
It stays on when operating in diameter mode. In this mode, the DRO displays
twice the actual axis movement. To access it or quit it, use this key if allowed
by installation parameter PAR04.
It stays on when working in inches and off when doing it in millimeters. To
access it or quit it, press this key.
This key toggles the display format for the rotary axis between decimal
degrees and Degrees.Minutes.Seconds.
To get into and out of home search mode.
To access the special function (HOLD)
To select the axis or preset it with a certain value.
To zero the axis when the "quick zeroing" mode has been activated (see
PAR11 in the installation manual).
To turn the display off while keeping track of the axes position at all times.
To cancel or abort an operation already initiated.
To validate a preset value or another operation.
Beginning of preset when the "quick zeroing" mode has been activated (see
PAR11 in the installation manual).
Editing the tool length
To change the sign of the entered value or change from fine to coarse
resolution and vice versa.
Model 10i. It toggles between the display modes: Max, Min, Difference and
Normal.