Circuit interruption.
Troubleshooting
Short-circuit to positive:
Disconnect the injection loads relay (No. 28 on the electrical circuit diagram), turn the key
to the ON position and activate the injection loads relay through the diagnostic tool.
Verify the presence of voltage between injection loads relay connector PIN 1 and 2 toward
the wiring harness.
If no voltage is read, disconnect the control unit and verify insulation from battery positive
of the injection loads relay PIN 1 (or control unit PIN 22). If necessary, restore the wiring
harness.
Short-circuit to negative:
Disconnect the injection loads relay (No. 28 on the electrical circuit diagram) and the control
unit.
Verify ground insulation of the injection loads relay connector PIN 1 and 2 toward the wiring
harness: if there is no insulation, restore the wiring harness.
Open circuit:
Disconnect the injection loads relay (No. 28 on the electrical circuit diagram) and the control
unit.
Verify continuity of the wiring harness between the injection loads relay and control unit:
Injection loads relay PIN 1 - control unit PIN 22. If necessary, restore the wiring harness.

Coil

Function
It controls the ignition spark plug in order to gen-
erate the fuel ignition spark.
Operation / Operating principle
Inductive discharge system.
LEFT COIL
Level in electrical circuit diagram
Coils and injectors
Position
Centred under the fuel tank.
Connector: on the coil.
Electrical specifications
Primary winding resistance: 550 kΩ ±
10%