Z-Wave Supported Command Class - Philio PST07 Manual

3 in 1 multi
Hide thumbs Also See for PST07:
Table of Contents

Advertisement

NO
Name
Def.
Valid
.
Auto Report
8
12
0 ~ 127
Battery Time
Auto Report
LightSensor
12
9
0 ~ 127
Time
Auto Report
Temperature
10
12
0~ 127
Time
Auto Report
0 ~
11
30
Tick Interval
0xFF
12 Temperature
2
1~100
Differential
Report
Description
seconds per tick, default tick is 7 (70
seconds).
0 means never send turn off light
command.
The interval time for auto report the
battery level.
0 means turn off auto report battery.
The default value is 12. The tick time can
setting by the configuration No.11.
The interval time for auto report the
illumination.
0 means turn off auto report illumination.
The default value is 12. The tick time can
setting by the configuration No.11.
The interval time for auto report the
temperature.
0 means turn off auto report temperature.
The default value is 12. The tick time can
setting by the configuration No.11.
The interval time for auto report each tick.
Setting this configuration will effect
configuration No.8, No.9 and No.10.
The unit is 1 minute.
The temperature differential to report.
0 means turn off this function.
The unit is 0.5 Fahrenheit.
Enable this function the device will detect
per minutes.
And when the temperature is over 140
NO
Name
Def.
.
20
LightSensor
Differential
13
Report
PIR Trigger
14
1
Mode
PIR
15
2
NightLine

Z-Wave Supported Command Class

Command Class
Z-Wave Plus Info
Version
Manufacturer Specific
Security 2
8
Description
Valid
degree Fahrenheit, it will continue report.
Enable this functionality will cause some
issue please see the detail in the
"Temperature Report" section.
1~100% The LightSensor Differential to report.
0 means turn off this function.
The unit is percentage.
Enable this function the device will detect
every percentage.
And when the lightSensor is over 20
percentage, it will continue report.
PIR Trigger Mode
:
Mode1: Normal
1~3
Mode2: DayTime
Mode3: AtNight
PIR night line Lux conditions:
1~
LightSensor determines whether
10000
the level is night. (Unit 1Lux)
Version
Required Security Class
2
None
3
Highest granted Security Class
2
Highest granted Security Class
1
None

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pst07-aPst07-bPst07-cPst07-d

Table of Contents