Z-Wave Configuration Settings - Philio PAT12-A Quick Start Manual

Z-wave co2 sensor

Advertisement

Before starting the update, please remove the front case of the device otherwise the
hardware check will fail.
Let the controller into firmware update mode, and press the front tamper key once to
start the update.
After firmware download is complete, the LED light will flash intermittently.
Z-Wave Supported Command Classes
The device supports the security function.when the device include with
a security controller, the device will auto switch to the security mode.In
the security mode, the follow commands need using Security CC
wrapped to communicate.
Command Class
Z-Wave Plus Info
Association
Association Grp Info
Transport Service
Version
Manufacturer Specific
Device Reset Locally
Powerlevel
Security 2
Configuration
Notification
Security 0
Sensor Multilevel
Version Required Security Class
2
None
2
Highest granted Security Class
1
Highest granted Security Class
2
None
3
Highest granted Security Class
2
Highest granted Security Class
1
Highest granted Security Class
1
Highest granted Security Class
1
None
1
Highest granted Security Class
8
Highest granted Security Class
1
None
11
Highest granted Security Class
Supervision
Firmware Update Meta Data

Z-Wave Configuration Settings

Size
NO. Name
(Byte)
Auto report CO2 Concentra-
1
tion time
CO2 Concentration differen-
2
tial report
3
Baseline level 1
4
Baseline level 2
5
Baseline level 3
6
Baseline level 4
7
Baseline level 5
4
1
None
4
Highest granted Security Class
Valid
Def. Description
2
1~32767
60
Units of 1 minute.
Units of 1 %.
1
0~100
10
0 means turn off the report
Units of 100 ppm.
1
0~50
0
0 means turn off the report
Units of 100 ppm.
1
0~50
0
0 means turn off the report
Units of 100 ppm.
1
0~50
0
0 means turn off the report
Units of 100 ppm.
1
0~50
0
0 means turn off the report
Units of 100 ppm.
1
0~50
0
0 means turn off the report