Specifications; Z-Wave Supported Command Class - Philio PSP01 Manual

Slim multi-sensor
Table of Contents

Advertisement

Turn Off Light
9
4
Time
Auto Report
Battery Time
10
12
Auto Report
12
Illumination
12
Time
Auto Report
13
Temperature
12
Time

Z-Wave Supported Command Class

COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_VERSION
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_BATTERY
COMMAND_CLASS_BASIC
PIR not detecting.
After turn on the light, setting the delay
time to turn off the light when the PIR
4~127
motion is not detected. 8 seconds per
tick, and minimum time is 32 seconds,
default tick is 4 (32 seconds).
The interval time for auto report the
battery level. 30 minutes per tick and
1~127
minimum time is 30 minutes, default tick
is 12 (6 hours).
The interval time for auto report the
illumination. 30 minutes per tick and
1~127
minimum time is 30 minutes, default tick
is 12 (6 hours).
The interval time for auto report the
temperature. 30 minutes per tick and
1~127
minimum time is 30 minutes, default tick
is 12 (6 hours).

Specifications

Power by CR123A lithium battery.
Signal (Frequency):
868.42 MHz(EU),
908.42 MHz(US),
922~926 MHz(JP/TW)
Range:
Minimum 30 meters indoor,
70 meters outdoor line of sight.
Operating Temperature: -10
For indoor use only.
Specifications subject to change without notice due to continuing
product improvement.
9
o
C ~ 40
o
C