Philio PST07 Manual page 4

3 in 1 multi
Hide thumbs Also See for PST07:
Table of Contents

Advertisement

Notice 1: Always RESET a Z-Wave
Z-Wave
TM
network
Z-Wave
TM
Notification
After the device adding to the network, it will wake-up once per day in
default. When it wake-up it will broadcast the "Wake Up Notification"
message to the network, and wake-up 10 seconds for receive the
setting commands.
The wake-up interval minimum setting is 30 minutes, and maximum
setting is 120 hours. And the interval step is 30 minutes.
If the user want to wake-up the device immediately, please remove the
front cover, and press the tamper key once. The device will wake-up 10
seconds.
Z-Wave
TM
Message Report
When the PIR motion triggered, the device will report the trigger event
and also report temperature and illumination level.
* Motion Report:
When the PIR motion detected, the device will unsolicited to send the
report to the nodes in the group 1.
Notification Report (V8)
Notification Type: Home Security (0x07)
Event: Motion Detection, Unknown Location (0x08)
* Tamper Report:
The tamper keys are pressed over 5 seconds. The device will into the
alarm state. In that state, if any one of the tamper keys be released,
the device will unsolicited to send the report to the nodes in the group
1.
TM
device before trying to add it to a
Notification Report (V8)
Notification Type: Home Security (0x07)
Event: Tampering. Product covering removed (0x03)
* Temperature Report:
When the PIR motion detected state changed, the device will
unsolicited to send the "Sensor Multilevel Report" to the nodes in the
group 1.
Sensor Type: Temperature (0x01)
*** Temperature differential report ***
This function default is enabled, to disable this function by setting the
configuration NO.12 to 0.
In the default, when the temperature is changed to plus or minus one
degree Fahrenheit (0.5 degree Celsius), the device will report
temperature information to the nodes in the group 1.
Caution 1: Enable this functionality, it will cause the PIR Motion to
disable detection when the temperature measurement. In other words,
The PIR motion will blind one second in every one minute.
* LightSensor Report:
When the PIR motion detected state changed, the device will
unsolicited to send the "Sensor Multilevel Report" to the nodes in the
group 1.
Sensor Type: Luminance (0x03)
*** LightSensor differential report ***
This function default is disabled, to enable this function by setting the
configuration NO.13 not to zero.
And if the LightSensor is changed to plus or minus the value (setting by
the configuration NO.13), the device will report illumination information
to the nodes in the group 1.
Caution 1: Enable this functionality, it will cause the PIR Motion to
disable detection when the illumination measurement. In other words,
The PIR motion will blind one second in every one minute.
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pst07-aPst07-bPst07-cPst07-d

Table of Contents