Gas Connection (If Fitted) - Astoria 1GR Use And Maintenance Manual

Table of Contents

Advertisement

The electrical system must be equipped with a
protection device (8) that ensures an omnipolar
disconnection from the mains with a contact
opening distance in overvoltage category III conditions
and which guarantees a suitable residual-current device,
equal to 30 mA, in compliance with current laws and
safety regulations.
Always connect the motor pump cable before
the machine power supply cable, by following
the diagram provided. Failure to comply with
the instructions given above may cause serious damage
to the machine and/or motor pump and will invalidate
any guarantee.
We recommend that you promptly report any problems
encountered during the appliance's installation to the
Manufacturer.
5.8 Gas connection (if fitted)
5.8.1
Requirements
When operating on gas, the machine emits
combustion fumes directly into its surrounding
environment; therefore, gas-powered machines
must not be installed in rooms with a volume of less than
12 m³, as described by the current standards. When in-
doors, always provide air vents so that any gas leaks can
escape.
Do not under any circumstances attempt to light the gas
without first installing the proper injector.
Do not start up the gas burners when the heating unit is
empty.
FOR ITALY
The system and installation of the appliances
must be performed in compliance with the cur-
rent UNI-CIG 8723 standards of the Ministerial Decree
of 12 April 1996.
TECHNICIANS' manual
FOR GERMANY
The following requirements must be observed
for installation:
• The regulation regarding the local police and the fire
department.
• The regulation regarding the workplace.
• The technical regulation on suction in terms of fire-
proofing.
• DVGW G634 worksheet: "technical rules for stoves-
gas appliances".
• DVGW G600 worksheet: "technical rules for gas
installations".
• Technical rules (TRF) for liquid gas installations.
• Rules regarding accident prevention.
• Gas supplier rules.
Gas system connection
5.8.2
To connect the gas system, proceed as follows:
• Install a gas shut-off valve upstream of the machine (A).
• Install a gas pressure reducer upstream of the machine
(B).
• The gas must be connected to the machine via a pipe in
accordance with the current regulations of the country of
installation using either a hose or rigid pipe.
A
B
31