Astoria 1GR Use And Maintenance Manual page 31

Table of Contents

Advertisement

5.8.3
Gas table
Instructions for installing the appropriate injector and adjust-
ing the air extraction guard.
Gas
Supply
type
pressure
MODEL
mbar
20
G20
20
G25
1 Group
G25.3
20/25
28-30/37
G30/31
50
G30/31
20
G20
20
G25
2 Groups
20/25
G25.3
28-30/37
G30/31
50
G30/31
20
G20
20
G25
3 Groups
20/25
G25.3
G30/31
28-30/37
50
G30/31
20
G20
20
G25
4 Groups
20/25
G25.3
28-30/37
G30/31
50
G30/31
TECHNICIANS' manual
Injector inlet
Burner
minimum pressure
injector hole
mbar
1/100 mm
1.7
100
1.7
110
2.4
100
3.5
60
3.5
60
1.9
110
2.1
135
2.7
110
5.5
75
6.1
65
2.3
135
2.3
145
3.5
135
6.1
80
11.3
75
2.5
145
2.5
160
3.8
145
6.8
85
11.3
75
INTERNATIONAL SYSTEM-CONVERTED
(SI) UNITS OF MEASUREMENT
1 mbar
=
1 mm
=
1 kW
=
3
1 m
/h
=
1 kg/h
=
Air intake extraction
Minimum power
guard
Q min
mm
kW
1
0.47
1
0.47
1
0.47
3
0.47
3
0.47
1
0.69
1
0.69
1
0.69
3
0.69
3
0.69
1
1.16
1
1.16
1
1.16
3
1.16
3
1.16
1
1.30
1
1.30
1
1.30
3
1.30
3
1.30
100
PA
0.001
m
1000
W
2.78 x 10 -4
3
m
/s
2.78 x 10 -4
kg/s
Maximum power
Maximum
Q n
consumption
kW
m
/h
3
1.67
0.177
1.67
0.177
1.55
0.164
1.40
-
0.110
1.80
-
0.142
2.03
0.215
2.52
0.267
1.88
0.199
2.20
-
0.174
2.10
-
0.167
3.06
0.323
2.91
0.308
2.85
0.302
2.51
-
0.199
2.84
-
0.225
3.55
0.376
3.55
0.376
3.30
0.349
2.85
-
0.225
2.85
-
0.225
33
kg/h
-
-
-
-
-
-
-
-
-
-
-
108
of

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Compr.2gr3gr4gr

Table of Contents