Astoria 1GR Use And Maintenance Manual page 75

Table of Contents

Advertisement

13.5.12 Wiring diagram code 18090047 - 18090048 *GICAR*
R
S
T
N
GV
MA BL NE GR
CAB
13
9
5
1
15
11
7
3
CO
16
12
8
4
14
10
6
2
MA
BL
PR
CT
IST
LA
IM1
RO
BL
RO
VE
GV
IM2
RO
BL
RO
VE
IM3
RO
BL
RO
VE
CV1
EVT
EVV
VE
EV1
VE
VE
EVC
VE
VE
EV3
VE
BL
RO
EV2
F1
FP2
FP1
MP
INSERTED
JUMPER
JP1
Serial transmission enabled Serial transmission disabled
JP2
Pre-infusion enabled
JP3
Programming switch connection
JP4
Filling the heating unit with the pump Filling the heating unit without the pump
JP5
Tea switch connection
JP6
Dispensing tea with the pump Dispensing tea without the pump
JP7
Continuous function disabled Continuous function enabled
TECHNICIANS' manual
SA
RE
SCT
O
O
O
CV2
CV3
JP19
JP16
CN19
JP8
JP1
JP17
JP9
JP2
JP18
JP15
JP7
CN14
CN18
CN12
CN11
CN10
NOT INSERTED
JUMPER
JP8
Pre-infusion disabled
JP9
JP15
JP16
JP17
JP18
LST
SL
CAL
JP4
JP21
JP6
CN5
F2
JP14
JP12
+5V
TXD
RXD
GND
TRF1
CN4
JP3
JP5
MB
INSERTED
NOT INSERTED
Dose count enabled
Dose count disabled
Credit/Debit enabled
Credit/Debit disabled
Display function buttons enabled Display function buttons disabled
6-button pushbutton panel enabled 4-button pushbutton panel enabled
Heating unit temp. check with external pressure switch (always on)
Heat.temp./press. management always ON (always inserted)
BI
White
BL
Blue
CAB
Power cable
CAL
Heating unit
CN1
Power supply connector
CN2
Low voltage connector
CN4
Serial transmission connector
CN10 PB panel connector GR1
CN11 PB panel connector GR2
CN12 PB panel connector GR3
CN14 Steam outlet connector
CN18 Connector Warmer connect.
CN19 Cup warmer heating el. connector
CO
Power switch
CT
Power supply connector
CV1
Flow meter GR1
CV2
Flow meter GR2
CV3
Flow meter GR3
EV1
GR1 solenoid valve
EV2
GR2 solenoid valve
EV3
GR3 solenoid valve
EVC
Filling solenoid valve
EVT
Tea solenoid valve
EVV
Steam solenoid valve
F1
Inlet fuse (6.3 A)
F2
Motor pump fuse (500 mA)
FP1(*) Motor pump fuse UL (OPD) fuse
FP2(*) 230 V UL (OPD) fuse
GR
Grey
GV
Yellow-green
IM1
GR1 manual switch
IM2
GR2 manual switch
IM3
GR3 manual switch
CN2
IST
Cup warmer switch
MA
LA
Indicator light
MA
MA
MA
Brown
NE
MB
Pushbutton panel membrane
BL
MP
Motor pump
NE
NE
Black
P5
Tea dose
BI
P6
Not managed
P7
Serial connection
RO
P9
Steam outlet connector
CN1
P10
Low voltage connector
P11
Power supply
PR
Pressure switch
RE
Heating element
RO
Red
SA
Safety heating element
SL
Heating unit level probe
TRF1 Transformer
VE
Green
( * ) Fuses for UL versions where
a plug with a capacity greater
than 30 A is installed
77
108
of

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Compr.2gr3gr4gr

Table of Contents