(4) Main differences and compatibilities with the FR-F500(L) series
Item
Simple mode parameters 61
Pr. 0 Torque boost initial value
00250 to 01160:2%
User group 1 (16), user group 2 (16)
(Pr. 160, Pr. 173 to Pr. 175)
Changed/cleared
functions
User initial value setting (Pr. 199)
Intelligent optimum acceleration/deceleration
(Pr. 60 setting "3" and Pr. 61 to Pr. 63)
Automatic torque boost
(Pr. 38, Pr. 39)
Advanced PID (pump function)
Pr. 500 to Pr. 516
Terminal block
Removable terminal block
PU
FR-PU04, DU04
Computer link, relay output option
Plug-in option
FR-A5NR
Three boards can be mounted
FR-F740-00023 to 00083, 00170, 00470, 00770 to 01160 are compatible in mounting dimensions
Installation size
Appendix 3-2 Replacement of the FR-A100 <EXCELENT> series
Instructions for installation
• When using the installation holes of the FR-A100(E) series, FR-A5AT (intercompatibility attachment) is necessary.
FR-F500(L)
Dedicated plug-in option (not compatible)
For other capacities, an optional intercompatibility attachment (FR-AAT) is necessary.
For customers who have replaced the older model with this inverter
Simple mode parameters 15
Pr. 0 Torque boost initial value
initial value
00250 to 00770: 2%, 00930, 01160: 1.5%
(When the torque boost value of the FR-F500 series
used was the initial value, it is not necessary to change
the torque boost value from the initial value when
replacing with the FR-F700 series.)
User group (16) only
Setting methods were partially changed
(Pr. 160, Pr. 172 to Pr. 173)
"User initial value setting" (Pr. 199) was cleared
Substitutable with the copy function of the operation
panel (FR-DU07)
Function was cleared
For deceleration time, overvoltage alarm can be
avoided with regeneration avoidance function (Pr. 882
to Pr. 885).
Automatic torque boost was cleared because of
addition of "Simple magnetic flux vector" (Pr. 80)
Parameter number change
Pr. 575 to Pr. 591
Removable terminal block
Priority compatibility (Terminal block of the F500 can be
mounted)
FR-DU07
FR-DU04 unavailable (Partly restricted when the FR-
PU04 is used. Refer to page 130.)
Built into the inverter
(RS-485 terminal, relay output 2 points)
One board can be mounted
FR-F700