Parameter
Name
Frequency setting/
161
key lock operation
selection
162 to 165
Refer to Pr.57 and Pr.58.
166, 167
Refer to Pr.150 to Pr.153.
168, 169
Parameter for manufacturer setting. Do not set.
170, 171
Refer to Pr.52.
172 to 174
Refer to Pr.160.
STF terminal
178
function selection
STR terminal
179
function selection
RL terminal function
180
selection
RM terminal
181
function selection
RH terminal
182
function selection
RT terminal function
183
selection
AU terminal
184
function selection
JOG terminal
185
function selection
CS terminal
186
function selection
MRS terminal
187
function selection
STOP terminal
188
function selection
RES terminal
189
function selection
Incre
Initial
Range
ments
Value
Setting dial frequency
0
setting mode
Setting dial
1
potentiometer mode
1
0
Setting dial frequency
10
setting mode
Setting dial
11
potentiometer mode
0 to 8, 10 to
14, 16, 24,
1
60
25, 37, 60,
0: Low-speed operation command
62, 64 to 67,
1: Middle-speed operation command
9999
2: High-speed operation command
3: Second function selection
0 to 8, 10 to
4: Terminal 4 input selection
14, 16, 24,
5: Jog operation selection
1
61
25, 37, 61,
6: Selection of automatic restart after
62, 64 to 67,
9999
7: External thermal relay input
1
0
8: Fifteen speed selection
10: Inverter operation enable signal (FR-HC,
0 to 8,
1
1
10 to 14, 16,
11: FR-HC, MT-HC connection,
24, 25, 37,
62, 64 to 67,
1
2
12: PU operation external interlock
9999
13: External DC injection brake start
14: PID control valid terminal
1
3
16: PU-external operation switchover
0 to 8,
24: Output stop
10 to 14, 16,
25: Start self-holding selection
1
4
24, 25, 37,
37:Traverse function selection
62 to 67,
60: Forward rotation command (assigned to
9999
61: Reverse rotation command (assigned to
1
5
62: Inverter reset
63: PTC thermistor input (assigned to AU
1
6
0 to 8,
10 to 14, 16,
64: PID forward/reverse action switchover
1
24
24, 25, 37,
65: PU-NET operation switchover
62, 64 to 67,
66: External-NET operation switchover
9999
1
25
67: Command source switchover
9999: No function
1
62
Extended parameters
Description
key lock mode
invalid
Key lock mode
valid
instantaneous power failure
MT-HC, FR-CV connection)
instantaneous power failure detection
STF terminal (Pr.178) only)
STR terminal (Pr.179) only)
terminal (Pr.184) only)
All
Param
Param
param
eter
eter
eter
copy
clear
clear
: enabled
× : disabled
×
×
×
×
×
×
×
×
×
×
×
×
×
121