SC No.
Level
361-01
B
SC No.
Level
362-01
B
Error Name/Error Condition/Major Cause/Solution
TD sensor output upper limit error (K)
TD sensor output:
The Vt (SP2-220-004) output continuously exceeds the upper limit
threshold value (SP2-992-001) for the time of the upper limit threshold
(SP2-992-003).
TD sensor is not connected correctly.
• Check if the TD sensor connector is connected.
• Check the harness of the TD sensor (disconnected, etc.).
• Replace the development unit if some error is detected.
Error Name/Error Condition/Major Cause/Solution
TD sensor output lower limit error (K)
TD sensor output:
The Vt (SP2-220-004) output is continuously below the lower limit
threshold value (SP2-992-002) for the time of the lower limit threshold
(SP2-992-004).
TD sensor is not connected correctly.
• Check if the TD sensor connector is connected.
• Check the harness of the TD sensor (disconnected, etc.).
• Replace the development unit if some error is detected.