The camera can provide a Strobe Out output signal. The signal goes high when the exposure time for each
frame acquisition begins and goes low when the exposure time ends as shown in Figure 9.35. This signal can be
used as a flash trigger and is also useful when you are operating a system where either the camera or the object
being imaged is movable. Typically, you do not want the camera to move during exposure. You can monitor the
Strobe Out signal to know when exposure is taking place and thus know when to avoid moving the camera.

9.20 Event Control

VA GigE camera provides an Event Notification feature. With the Event Notification feature, the camera can
generate an event and transmit a related event message to the PC whenever a specific situation has occurred.
The camera can generate and transmit events for the following type of situation:
The end of an exposure has occurred (Exposure End)
XML parameters related to Event Control are as follows.
XML Parameters
EventSelector
EventControl
Event Notification
TransportLayer
GevTimestampControlLatch
Control
GevTimestampControlReset
Figure 9.30 Strobe Out Signal (not drawn to scale)
ExposureEnd
On
Off
Table 9.21 XML Parameters related to Event Control
81 of 94
Value
Select which particular event to control
Exposure End event is only available
Enable the selected event notification
Disable the selected event notification
Latch the current time stamp counter into
-
GevTimestampValue.
-
Reset the time stamp counter to 0.
VA GigE series
Description
RA14-131-003