XML parameters related to Flat Field Correction are as follows.
XML Parameters
FfcTargetLevel
FlatFieldCorrection
†: If the current setting values for the Binning Horizontal and Binning Vertical parameters are different from
the setting values at the time when you generate the Flat Field data, the Flat Field Correction feature is not
available even if you set the Ffc Mode parameter to On.
Value
Off
FfcMode
On
0~4095
FfcFrames
1,2,4,8,16
-
FfcGenerate
-
FfcSave
-
FfcLoad
Table 9.16 XML Parameters related to Flat Field Correction
74 of 94
Description
Flat Field Correction Off
Enable the Flat Field Correction feature
Set the average grey level for image background
Set the number of frames to be acquired when
generating the Flat Field data. The more frames result
in the better data; however it takes more time to
generate the data.
Generate the Flat Field data
Save the generated Flat Field data in the non-volatile
memory. The generated data by executing the
FfcGenerate parameter are saved in the volatile
memory and the data are lost if the camera is reset or if
power is turned off. To use the data after the camera is
powered on or reset, save them in the non-volatile
memory.
Load the Flat Field data from the non-volatile memory
into volatile memory
VA GigE series