9.19 Digital IO Control

The pin number 3 of the control receptacle is designated as programmable output and can be operated in
various modes.
XML parameters related to Digital IO Control are as follows.
XML Parameters
LineInverter
LineSource
DigitalIO
Control
UserOutputValue
PulsePeriod
PulseWidth
StrobeOutDelay
Value
On
Invert the output signal of the line
Off
Do not invert the output signal of the line
Off
Disable the line output
ExposureActive
Output pulse signals indicating the current exposure time
FrameActive
Output pulse signals indicating a frame readout time
StrobeOut
Output Exposure Active signals with Strobe Out Delay
PulseGenerator
Output user defined pulse signals
UserOutput
Output User Output signal set by User Output Value
On
Set the bit state of the line to High
Off
Set the bit state of the line to Low
1~60,000,000
Set a pulse period in microseconds when the Line Source
is set to Pulse Generator
0~60,000,000
Set a pulse width in microseconds when the Line Source
is set to Pulse Generator
0~65535
Set a delay in microseconds when the Line Source is set
to Strobe Out
Table 9.20 Digital IO Control