Connection Of The Power Supply And Drive - RADEMACHER ReWiSo 2696 Instruction Manual For The Electrical Connection And For Commissioning

Table of Contents

Advertisement

i
Installation of the weather station and connection of the drive
1
Cable connection to the precipitation sensor in the housing cover
2
Drive connections (spring-loaded terminal, PE/N/Up/Down), suitable for solid
conductors up to 1.5 mm² or fine-wire conductors
3
Opening for drive cable
4
Power supply connections (230 V / 50 Hz, spring-loaded terminal, L1/N/PE),
suitable for solid conductors up to 1.5 mm² or fine-wire conductors
5
Opening for power supply cable
6
Fine fuse 6.3 A
7
Programming LED. During normal operation, this LED indicates the reception
of a valid data packet
8
Programming button for teaching-in the radio connection to the operating unit

Connection of the power supply and drive

The drive of the awning or Venetian blind is connected to the weather station. Several
drives can be connected in parallel. When connecting motors in parallel, check whether
a group control relay is prescribed by the motor manufacturer. Group control relay can
be ordered from RADEMACHER.
If motors are connected in parallel that are not suitable for this, these and the
controller will be damaged.
Motors with a power consumption higher than 1000 watts must be operated via a relay
or contactor with a separate mains lead.