OPERATION
5
B3, logbooks
Level
Designation / function
This menu groups several functions which allow to display the corresponding actual reading.
B3.1
B3.1
status log
B3.1
B3.1
B4, information
Level
Designation / function
This menu groups several other menus which contain device specific information.
B4.1
B4.1
B4.1
B4.1
Device serial no.
B4.2
B4.2
Mainboard
B4.2
B4.2
B4.3
B4.3
B4.3
B4.3
Sensor electronic

5.6.3 Menu C, setup

C1, measuring
Level
Designation / function
This menu groups several other menus in which the measuring functions can be set.
C1.1
Measuring function
C1.2
Measuring mode
C1.3
Definition fluff
C1.4
Def. sludge blanket
C1.5
Hysteresis
C1.6
Tracking time
C1.7
Tracking position
C1.8
Start signal
C1.9
Timer interval
C1.10
Units
C1.10.1
Height / Depth
C1.10.2
Temperature
C1.10.3
Concentration
46
Settings / descriptions
Log for information, errors and warnings.
Settings / descriptions
This menu shows the serial number of the device
This menu gives information about the main board.
1st line: ID No. of the circuit board
2nd line: software version
3rd line: production date
This menu gives information about the sensor electronic.
1st line: ID No. of the sensor
2nd line: software version
3rd line: production date
Settings / descriptions
This menu shows the different measurement functions: "Level", "Profile",
"Zone Tracking" and "Manual operation".
This menu shows the different measurement mode of the level
measurement and can be switched from "Depth" to "Height".
This menu shows the concentration of the fluff and can be set.
This menu shows the concentration of the sludge blanket and can be set.
This function allows to set the hysteresis value of the zone tracking mode
(This menu is displayed only if zone tracking is selected in C3.1.1); Range:
0...5 g/l
Definition time period the sensor is remaining in parking position, when
elapsed the sludge level will be tracked again (This menu is displayed only if
zone tracking is selected in C3.1.1); Range: 20...999 s
Definition of the relative parking position of the sensor above the sludge
level (This menu is displayed only if zone tracking is selected in C3.1.1);
Range: 0.05-0.3 m
This menu shows the start signal for the measurement and can be selected
between "Timer" (via build in timer) or "Trigger input" (via external switch on
control input 1 and/or 2).
This menu shows the timer interval for starting the measurement and can
be set in minutes. (This menu is displayed only if "Timer" is selected in C1.6.)
This menu groups several functions to define the units of the measuring
results. These units are used for all values of the related unit group on the
display (measuring screen and parameters).
This function allows to define the unit for level measurement. Options: m,
feet, inch, cm
This function allows to define the temperature unit. Options: °C, °F, K
This function allows to define the concentration unit. Options: g/l, mg/l