Clamp-On Liquid Tool; Figure 6-11 Clamp-On Liquid Sizing - Siemens SITRANS F FS200 Utility Programming Manual

Ultrasonic flowmeters
Table of Contents

Advertisement

Utility Screens

6.4 Clamp-On Liquid Tool

The [Liquid Sensor Selection and Sizing Tool] screen allows the user to specify units of
measure, pipe dimensional data, liquid type, along with nominal values for flow range, and
temperature range. These values are used by the sizing tool to calculate the recommended
sensor selection (type and size) along with the recommended sensor installation methods.
The tool also provides application calculations for flow velocity, Reynolds number, Std
Volume compensation factor, expected repeatability and will point out if an application
conflict exists.
Liquid Sensor Selection and Sizing Tool Screen
To display the [Liquid Sensor Selection and Sizing Tool] screen:
1. In the [Utilities] drop down menu select [Clamp-On Liquid Tool].
2. Input your default units of measurement in the row at the top of the screen
3. Select your pipe material from the drop-down menu, then enter your pipe's Outside
diameter and Wall thickness as accurately as possible.
4. Select a liquid type from the [liquid Properties] drop down menu. Enter the Min / Max flow
range for your application (be careful to use the units of measure and multiplier shown), lastly
enter the Min / Max temperature.
5. Click the [Calculate] button. The FS200 Clamp-On liquid tool will compute the
Figure 6-11 Clamp-On Liquid Sizing Screen
FS200 Programming Manual, 03/2020,
A5E02951525-AB
recommended sensor type and size for your specified pipe. It will also provide sensor
mounting mode and spacing information. An example appears below in Figure 6-11